34
Connecting the appliance
!
!
All electrical work should be carried out by a suitably qualified and authorized elec-
trician. No alterations or willful changes in the electricity supply should be carried
out.
The voltage and the supply frequency are showed on the rating plate. The cabling and wiring system
must be able to bear the maximum electric power required by the oven. This is indicated on the specifi-
cations plate. If you are in any doubt at all, please contact the manufacturer-supplier services
agent or similar qualified personal.
The socket shall be connected according to the relevant standard or connected to a single-pole cutout
3.0 minimum supply.
Connection diagram
Caution! Voltage of heating elements 230V.
Caution! ln the event of any connection
the earth wire must be connected to the PE
terminal.
For 220–240V AC, one-phase connection,
bridges connect 1-2-3 terminals and 4-5
terminals, the earth wire from hob to PE.
L1, L2, L3 = Phase, N = Neutral, PE = Earth
For 220–240V AC, two-phase connection, bridges
connect1, 2-3 terminals and 4-5 terminals, the
earth wire from hob to PE.
For 220–240V AC, three-phased connection,
bridges connect 4-5 terminals, phases in
succession 1,2 and 3,earth to 4-5,the earth
wire to from hob to PE.
1
2
3
Recommended
type of connec-
tion lead
Installation and connection of the device