The actual product may differ from
the images in the manual.
- 26 -
ERROR CODE LIST & TROUBLESHOOTING
ERROR
CODE
ERROR CODE DESCRIPTION
CHECKLIST
01
Not detecting flame normally
Broken Photocell sensor
Not enough fuel in the tank
02
Supplied electricity, but heater not working
Check heater for short
(infinity resistance means short)
Broken load detector for heater
03
Clogged fuel in feeding pipe
(Limit switch on feeding pipe activated)
Excessive fuel supply (adjust the fuel supply)
Fuel not supplied due to excessively low fuel hose
Broken limit switch on feeding pipe
04
Water temperature sensor not reading
temperature measurements
Defectiv e or broken water temperature sensor
06
Not reading the blower RPM
Defectiv e or broken blower connection
07
Blower RPM out of range
Clogged tubes or flue
08
Poor communication with room thermostat
Defectiv e or broken connection with room thermostat
91
Not detecting flame after ignition
Clogged tubes or flue
Improper cleaning of ash cleaner
95
Not sensing low water level in the heat
exchanger
Defectiv e earth connection (black color) or
low water lev el sensor
96
Sensor sensing more than 91
water
℃
temperature
Defectiv e circulation pump operation or poor plumbing
98
Activation of ov er heating bimetal on burner
parts
Poor sealing of fuel parts and defective burner