8. TROUBLESHOOTING GUODE (ERROR CODE)
※ If any abnormality is found during the operation of the boiler, do not take any measures to repair them at your
own discretion; instead, refer to the below-stated issues. If any abnormality is generated in the boiler, the figures
flash on the display part of the room thermometer depending upon the state. If an abnormal state carries on,
contact the distributor.
- The connecting cable of the room thermostat is excessively long (≥ 10M) or the connecting cable has come
into contact with a high-voltage cable or telephone cable. In specific cases, using a special cable is - required for
reinstallation.
- Contact a local distributor or A/S center.
- The water temperature sensor in the boiler has a problem.
- Stop the operation of the boiler and contact a local distributor or A/S center.
“04” flashes on
the room
thermostat
“08” flashes on
the room
thermostat.
Troubleshooting
"01,” “02,” or
“03” flashes on
the room
thermometer
Code
8-1 FINDING FAULT
-
Ignition is not done or ignition is done but has immediately shutdown due to a disorder in flame detection. This
may not be the trouble of the boiler and may be temporarily due to an outside condition. Push the Power/Restart
button of the room thermostat in order to restart the boiler.
-
If the abnormality continues, contact a local distributor or A/S center.
The water is insufficient in the boiler. If the water is insufficient, the water is automatically supplied and, when the
water becomes sufficient, the boiler works properly.
If release is not performed continuously and makeup water is not supplied, contact a local distributor or A/S
center.
“95” flashes on
the room
thermostat
-
The contact for the blowing/exhaust fans is wrong.
-
The circulation point of the heat exchanger is reached.
- If release is not done continuously, contact a local distributor or A/S center.
“96” flashes on
the room
thermostat
- The overheat safety device is activated and the operation of the boiler is suspended because the heating water
temperature of the boiler is excessively high.
- In this case, the circulation pump should be activated and it will reduce the heating water temperature of the
boiler.
The
Blowing/Exhaus
t fans do not
work.