2-6
4-Wire Electrical Connection
1.
Remove the ground-link screw from the
range frame and set the screw aside.
2.
Bend the ground link up so that it does not
contact the range.
3.
Connect the green ground wire on the
power supply cord to the ground link screw
hole in the range with the ground-link
screw you removed earlier. Make sure
that the bare ground wire does not contact
the adjacent terminal block connections.
NOTE: Do not loosen the factory-installed nuts
on the terminal block when you perform the
following steps.
4.
Connect the neutral (white) wire of the
power supply cord to the center, silver-
colored terminal screw on the terminal
block, and secure it with one of the 3/8
″
brass nuts that you set aside earlier.
5.
Connect the remaining two power supply
cord wires to the outer terminals of the
terminal block, and secure them with 3/8
″
brass nuts.
6.
Tighten the strain relief screws to secure
the power supply cord.
7.
Install the terminal block cover.
ground link
ground-link
screw
ground-link
screw
bare wire
from power
supply cable
U.L. listed conduit
connector and power
supply cable
neutral wire
(white wire)
bare wire
from power
supply cable
silver-colored terminal
block screw