14
7. The tank tray for the 20 lb LP gas fuel tank must be adjusted
so that the bottom of the tank tray is
¹⁄₈
" (0.32 cm) above the
cabinet door opening and is level. The top nut on each of the
mounting brackets is to be loose. Turn the bottom nuts
counterclockwise to raise the tank tray and turn the bottom
nuts clockwise to lower the tank tray. When the tank tray is
level and slides in and out without touching the cabinet door
opening at the bottom or top with the 20 lb LP tank installed,
tighten the top nuts against the adjustment flange.
NOTE: A bracket or shelf (not supplied) that is large enough
to keep a second 20 lb LP gas fuel tank from being stored in
the storage area under the side burner is required to be
mounted inside the island.
Make Gas Connection
Gas Connection to a 20 lb LP Gas Fuel Tank
If converting to local LP or Natural gas, follow the instructions in
the “Gas Conversions” section.
IMPORTANT: A 20 lb LP gas fuel tank must be purchased
separately.
IMPORTANT: The gas pressure regulator/hose assembly
supplied with the side burner must be used. Replacement gas
pressure regulator/hose assembly specific to your model, is
available from your outdoor side burner dealer.
To Install the 20 lb LP Gas Fuel Tank:
1. Open cabinet doors.
2. Pull out the tank tray.
3. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
4. Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
5. Screw the gas pressure regulator/hose assembly to the 20 lb
LP gas fuel tank as shown. (To disconnect, turn off the gas
supply to the 20 lb LP gas fuel tank, then unscrew the gas
pressure regulator/hose assembly from the 20 lb LP gas fuel
tank as shown.)
6. Turn on the gas supply. Wait a few minutes for gas to move
through the gas line.
7. Test all connections by brushing on an approved
noncorrosive leak-detection solution. Bubbles will show a
leak. Correct any leak found.
8. Slide tank tray back into the cabinet.
9. Go to “Plug in Side Burner” in this section.
A. Top nut loosened
B. Top nut tightened
A
B
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11” (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Tank tray
A. Locking screw
B. Mounting hole
C. Bottom collar
A. 20 lb LP gas fuel tank
B. Gas pressure regulator/hose assembly
A
B
C
A
B
connect
disconnect