4-22
REMOVING THE POWER SUPPLY CORD
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug refrigerator or disconnect power.
2. Pull the refrigerator away from the wall so
that you can access the rear of the unit.
3. Remove the six hex-head screws from
the unit compartment cover. Remove the
cover and slide the power supply cord
strain relief out of the slot in the cover.
Cover Screws
Power Supply Cord
4. Release the locking arms, and discon-
nect the power supply cord connector
from the main harness.
5. Remove the hex-head screw from the
green ground wire and remove the power
supply cord.
Ground Screw
Power Supply Cord Connector