3-10
HIDDEN BAKE ELEMENT
TEST PROCEDURE
Refer to page 2-23 for the procedure for ser-
vicing the hidden bake element.
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R x 1 scale.
3.
Disconnect the wires from the hidden bake
element terminals.
4.
Touch the ohmmeter test leads to the
bake element terminals. The ohmmeter
should indicate 25 to 30
Ω
.
Electrical Shock Hazard
Disconnect the electrical supply from the
unit before servicing.
Failure to do so could result in death or
electrical shock.
WARNING
Resistance Test (At The Electronic
Range Control)
NOTE: To test the hidden bake element at the
electronic range control, perform the following
steps (see page 2-4 for removing the top ac-
cess panel).
1.
Disconnect power from the range.
2.
Set the ohmmeter to the R x 1 scale.
3.
Disconnect the P5-2 (red) wire and the red
wire that is on the common side of the
double line break relay (refer to the sche-
matic) on the electronic range control.
4.
Touch the ohmmeter test leads to the two
red wires. The ohmmeter should indicate
25 to 30
Ω
.
Y
R
BU
R
R
ELECTRONIC RANGE
CONTROL
P5-5
P5-2
P5-1
DOUBLE LINE
BREAK RELAY
OVEN SHUTDOWN
THERMAL FUSE
NON-RESETTABLE
BROIL-3000W
BAKE-2000W
CONV-1600W
Disconnect This
Red Wire