4-18
Remove the unit compartment cover (see
page 4-15)
Use a small screwdriver to lift the wire retain-
er off of the Run Capacitor
Disconnect the wire connector from the Re-
lay / Overload.
1.
2.
3.
REmOVE THE RELAY / OVERLOAD & RUN CAPACITORS
Pull the Run capacitor and the Relay / Over-
load off the terminals of the compressor.
Pull the Run capacitor off the support rod of
the Relay / Overload.
4.
5.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Summary of Contents for Architect Series II KURO24LSBX
Page 12: ...2 4 NOTES ...
Page 14: ...3 2 NOTES ...
Page 44: ...4 30 NOTES ...
Page 50: ...5 6 NOTES ...
Page 53: ...7 1 WIRINGDiagrams Wine Cellar Wiring Diagram ...
Page 54: ...7 2 Beverage Center Wiring Diagram ...
Page 55: ...7 3 Undercounter Refrigerator Wiring Diagram ...
Page 56: ...7 4 NOTES ...
Page 58: ......