4-3
Locate the adhesive squares below the sep-
arator that cover the wires and connector.
Remove the adhesive squares carefully so
they can be reused during reassembly.
Disconnect the wire connector from the back
of the unit by pressing the locking tab and
pulling it out. (The Beverage Center will have
two connectors at the back of the unit.)
1.
2.
Remove the two screws, one at each side,
that secure the separator to the unit.
To remove the separator, grasp the front
edge with both hands and pull to release the
separator and remove it from the unit.
Remove the last two rack tracks that support
the separator.
3.
4.
5.
REmOVE THE SEPARATOR (UW, BC)
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Grasp and
pull with
both hands
Right side
screw
Adhesive
Squares
Summary of Contents for Architect Series II KURO24LSBX
Page 12: ...2 4 NOTES ...
Page 14: ...3 2 NOTES ...
Page 44: ...4 30 NOTES ...
Page 50: ...5 6 NOTES ...
Page 53: ...7 1 WIRINGDiagrams Wine Cellar Wiring Diagram ...
Page 54: ...7 2 Beverage Center Wiring Diagram ...
Page 55: ...7 3 Undercounter Refrigerator Wiring Diagram ...
Page 56: ...7 4 NOTES ...
Page 58: ......