background image

9

A.

Push in and turn the surface

burners and grille control knobs to “LITE”
position. For griddles, turn the griddle
control knob to a temperature degree
mark (300F° recommended). The surface
burner flame should light within 4
seconds and the grille and griddle flame
in 30-40 seconds.

NOTE: The griddle flame cannot be seen,
but you should hear it ignite and feel heat
from the griddle.

After lighting the burners, turn the control
knobs to “OFF”.

If burners do not light properly, turn
control knob to the “OFF” position. Check
that burner cap is in the proper position.
Check that circuit breaker or house fuse
has not blown. Check that the shutoff
valve is in the “ON” position. Check
operation again.

If a surface burner, grille or griddle does
not light at this point, contact your
KitchenAid dealer for assistance.

cooktop

burners

grille
knob

griddle

knob

valve
stem

C.

Check flame on “HI” for a blue

color. It should be clean and soft in 
character. No yellow tip, blowing or lifting
of flame should occur. Occasional orange
flashes are normal and reflect different
elements in the air or gas.

B.

Adjusting the surface burner or

grille flame:

NOTE: There is no adjustment for the
griddle flame. Gas flow is at 100%,
temperature is controlled by thermostat.

Push in and turn each control knob to the
“LO” position. The “LO” setting of each
burner has been factory set to the lowest
position available to provide reliable
reignition of the burner. If it does not stay
lit on the “LO” position, check “LO”
position as follows:

a. Turn control knob to “LITE” until burner

ignites.

b. Quickly turn control knob down to “LO”

position.

c. If burner goes out, readjust valve as

follows:

Remove control knob. Insert a flat-blade
screwdriver into the hollow valve stem
and engage the slotted screw. Flame size
can be increased or decreased by turning
the screw. Adjust flame until you can
quickly turn control knob from “HI” to “LO”
position without extinguishing the flame.
Flame should be as small as possible
without going out.

ports

typical surface
burner flame at
highest setting

18.

Electronic Ignition System —
initial lighting

Surface burners use electronic ignitors in
place of standing pilots. When the
cooktop control knob is pushed in and
turned to the “LITE” position, the system
creates a spark to light the burner. This
sparking continues until the control knob
is turned to the desired setting.

The grille and griddle burner use an
ignitor glow bar that is either on or off in
place of standing pilots. When the glow
bar is hot, it sends a signal back to the
safety valve which opens allowing gas 

to flow.

Check the operation of the
surface burners, grille and
griddle.

19.

Check operation of oven

element. Turn oven selector to “BAKE”.
“350F” will show on display. Press “Enter”.
First Preheat light comes on when oven
temperature begins to rise. When second
Preheat light comes on, open oven door
and hold hand above oven floor and feel
for heat. Do not touch oven floor. Press
“Cancel” and turn oven selector to
“Reset”.

20.

Check the operation of the

broiler element. Turn oven selector to
“BROIL”. “HI” will show on display. Press
“Enter”. Look through oven window. The
top element should glow red and heat
should be radiating out of the door. Press
“Cancel” and turn oven selector to
“Reset”.

If the oven does not operate, check that
power supply is turned on, that no fuses
are blown, or circuit breakers tripped. If
the oven still does not operate, contact
your KitchenAid dealer or designated
service company.

21.

Reinstall lower vent by inserting

tabs into the slots on the front trim. Push
vent upward until the holes line up at top
of vent. Reattach the vent using the two
screws.

22.

Place burner grates over

burner caps. The simmer plate may set
on one of the grates or be stored for
future use. (See Use and Care Guide.)

To get the most efficient use
from your new dual fuel range,
read your KitchenAid Use and
Care Guide. Keep Installation
Instructions and Guide close to
the range for easy reference.

Summary of Contents for 8301169

Page 1: ...uestions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 36 91 4 cm Commercial Style Dual Fuel Range with self cleaning thermal convection oven for residential use only OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF backguard required for some installations For the ...

Page 2: ...e below the control panel This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition installation codes WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damag...

Page 3: ...ons or other installations with more than 5 12 7 cm clearance to back wall use the optional stainless steel island trim included with the range to cover the backguard mounting flanges 36 91 4 cm min upper cabinet width 36 1 4 92 1 cm opening width 20 50 8 cm 12 30 5 cm 5 1 2 14 cm 8 20 3 cm 18 45 7 cm upper cabinet to countertop gas line opening to be located in this area junction box to be locate...

Page 4: ...n the same room but external to the range and should be in a location that allows ease of opening and closing Do not block access to the shutoff valve gas supply line shutoff valve open position G If rigid pipe is used as a gas supply line a combination of pipe fittings must be used to obtain an in line connection to the range All strains must be removed from the supply and fuel lines so range wil...

Page 5: ...ition and all local codes and ordinances C The range should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable The flexible armored cable extending from the fuse box or circuit breaker box should be connected directly to the junction box D Locate the junction box to allow as much slack as possible between the junction...

Page 6: ...ermit connecting the frame ground conductor to the neutral white junction box wire not used for Canadian installations Figure 2 Grounded neutral junction box red wires white wire white and bare grounding oven cable wires factory crimped 3 wire cable from power supply black wires 4 wire cable from range U L or CSA listed conduit connector 1 Disconnect power supply 2 Connect the flexible armored cab...

Page 7: ...heck connections again Clean all detergent solution from range 14 Put a burner cap on each burner base Place burner grates over burner bases and caps If your model has only surface burners no grille or griddle go to Check the operation of the surface burners grille and griddle on Page 9 If your model was shipped with a grille or griddle go to Installing the grille or griddle on Page 8 to complete ...

Page 8: ...the slot in the left rear corner of the wave tray H Place the wave plate on the wave tray as shown The wave plate must be centered on the wave tray E Plug power supply cord into grounded outlet C Plug power supply cord into grounded outlet I Install the grille grate A Place drip tray in the well at the front of the griddle Slide tray forward until it stops B Refer to the Use and Care Guide that ca...

Page 9: ... from HI to LO position without extinguishing the flame Flame should be as small as possible without going out ports typical surface burner flame at highest setting 18 Electronic Ignition System initial lighting Surface burners use electronic ignitors in place of standing pilots When the cooktop control knob is pushed in and turned to the LITE position the system creates a spark to light the burne...

Page 10: ...uld need service call the dealer from whom you purchased the appliance or a KitchenAid designated service company A KitchenAid designated service company is listed in the Yellow Pages of your telephone directory under Appliances Household Major Service and Repair You can also obtain the service company s name and number by dialing free within the continental United States the KitchenAid Customer I...

Page 11: ...R LATCH R V P7 5 SUPPRESSOR WP 4451985 ELECTRONIC CONTROL DOUBLE LINE BREAK RELAY TOD NON RESETABLE P9 1 P9 3 WISP CONNECTOR SEE BLOWER REMAINS OFF UNTIL OVEN REACHES 190 F 88 C AND MAY CONTINUE RUNNING UP TO 45 MINUTES AFTER OVEN HAS TURNED OFF LATCH ASSY F Y ORG 2 1 A BK W BK BK BK OFF AUTO LIGHT SWITCH LIGHT POWER SUPPLY BU BU P3 2 P3 3 BK Y P8 1 P8 3 Y P8 2 ORG P8 4 BK DOOR SWITCH 2 ON LATCH A...

Page 12: ...Part No 8301169 Rev A 2003 KitchenAid Registered Trademark Trademark of KitchenAid U S A KitchenAid Canada licensee in Canada Prepared by KitchenAid Benton Harbor Michigan 49022 Printed in U S A ...

Page 13: ...r au 1 800 422 1230 ou consulter notre site Internet à l adresse www kitchenaid com IMPORTANT Lire et conserver ces instructions Cuisinière style commercial 91 4 cm 36 po deux combustibles avec four autonettoyant thermique à convection pour utilisation résidentielle seulement OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Dosseret nécessaire pour certaines configurations d install...

Page 14: ...ue signalétique et l étiquette d information sur les gaz combustibles sous le tableau de commande de l appareil L installation réalisée selon ces instructions doit être conforme aux dispositions des codes et règlements locaux En l absence d un code local l installation doit être conforme aux dispositions de la plus récente édition de la norme American National Standard National Fuel Gas Code ANSI ...

Page 15: ...cm 8 po 45 7 cm 18 po entre placard mural et plan de travail Placer la canalisation de gaz dans cette zone Placer la boîte de connexion dans cette zone Dégagement de séparation de 4 po 10 2 cm min entre la cuisinière et un mur des matériaux combustibles des deux côtés de la cuisinière et au dessus de la surface de cuisson Dégagement de séparation de 0 po 0 cm entre les deux côtés et l arrière de l...

Page 16: ...e de gaz devra comporter un robinet d arrêt homologué Ce robinet d arrêt devrait être situé dans la même pièce que la cuisinière à un emplacement permettant un accès aisé pour les manoeuvres d ouverture et de fermeture Ne pas entraver l accès au robinet d arrêt canalisation d arrivée de gaz robinet d arrêt ouvert G Si la canalisation de gaz est une tuyauterie rigide utiliser une combinaison de rac...

Page 17: ... installation en îlot Ces articles emballés peuvent être placés dans la cuisinière ou sur la cuisinière La liste des pièces fournies avec la cuisinière dépend du modèle commandé 3 Placer sur le sol derrière la cuisinière un morceau de carton provenant du côté de l emballage Saisir fermement la cuisinière de chaque côté participation de deux personnes Soulever la cuisinière d environ 8 cm 3 po et t...

Page 18: ...on du circuit 2 Faire passer dans la boîte de connexion à travers un connecteur de conduit homologation UL ou CSA le câble blindé flexible provenant de la cuisinière Serrer les vis sur le connecteur de conduit 3 Avec des connecteurs de fils voir la Figure 1 connecter ensemble les deux conducteurs noirs et les deux conducteurs rouges 4 Séparer le conducteur nu et le conducteur blanc du câble de la ...

Page 19: ...re quelques minutes pour que le gaz expulse l air de la canalisation installation du dosseret installation de la garniture pour îlot trou central pas utilisé 3 vis avant 4 vis nécessaires à l arrière mais pas représentées appliquer un produit d étanchéité conduit de raccordement flexible raccord droit 1 2 po robinet d arrêt manuel canalisation de gaz 1 2 po à 3 4 po un filetage mâle de 1 2 po est ...

Page 20: ...e d utilisation et d entretien fourni avec la table de cuisson au sujet de la préparation de la plaque à frire avant la première utilisation et au sujet du nettoyage C Brancher le cordon d alimentation sur une prise de courant reliée à la terre D Contrôler les flammes des brûleurs standard et du brûleur de la plaque à frire Avant de terminer l installation du gril voir à la page 8 Contrôle du fonc...

Page 21: ...er en 30 à 40 secondes NOTE la flamme du brûleur de la plaque à frire n est pas visible mais on doit percevoir le son émis lors de l allumage et l échauffement de la plaque Après l allumage de chaque brûleur ramener le bouton de commande à la position d arrêt OFF Si un brûleur ne s allume pas correctement ramener le bouton de commande à la position d arrêt OFF Déterminer si le chapeau de brûleur e...

Page 22: ...n peut également téléphoner sans frais au Centre d assistance à la clientèle de KitchenAid au 1 800 422 1230 états continentaux des États Unis un opérateur spécialisé pourra alors communiquer le nom et l adresse du plus proche établissement de service après vente agréé KitchenAid Pour préserver la qualité incorporée dans cet appareil ménager KitchenAid confier les travaux à un établissement de ser...

Page 23: ... 120 V CA 60 HZ MONOPHASE 15 OU 20 A N BL ALLUMEUR DU GRIL CONTACTEUR ROBINET DU GRIL ÉLECTRODES D ALLUMAGE TABLE DE CUISSON N N N BL N BL L1 NEU BL N TERRE VERT BL BL MODULE D ETINCELAGE ÉLECTROVANNE DE LA PLAQUE À FRIRE 120 V CA 60 HZ MONOPHASE 15 OU 20 A N N BL L N G JAUNE OU MARRON 4 PLCS CONTACTEURS ROBINETS DES BRÛLEURS DE LA TABLE DE CUISSON THERMOSTAT DE LA PLAQUE À FRIRE N BL ÉLECTRODES A...

Page 24: ... P7 1 BL BL TAN TAN BL N BL R VENTILATEUR VOIR VERROUILLAGE PORTE MOTEUR DU LOQUET R V P7 5 DISPOSITIF ANTIPARASITE WP no 4451985 COMMANDE ÉLECTRONIQUE RELAIS DISJONCTEUR DEUX LIGNES T O D PAS RÉINITIALISABLE P9 1 P9 3 CONNECTEUR WISP LE VENTILATEUR RESTE ÉTEINT JUSQU À CE QUE LE FOUR ATTEIGNE 19O F 88 C ET PEUT CONTINUER DE FONCTIONNER JUSQU À 45 MINUTES APRÈS QUE LE FOUR EST ÉTEINT SYST DE VERRO...

Reviews: