background image

4.

Carefully move range

close to the cabinet opening. Place the
rack in oven. Place level on rack, first side
to side; then front to back.

If the range is not level, adjust the feet up
or down. Turn leveling leg sleeves to level
range and to raise or lower range to the
desired countertop height.

5

remove
screws

bottom
vent

leveling leg
sleeves

Electrical

requirements

F.

Connection at connection block must

be copper wire only.

If the house has aluminum wiring, follow
the procedure below:

a) Connect the aluminum wiring to the

copper wiring using special connectors
designed and Underwriters
Laboratories-listed for joining copper to
aluminum. Follow the electrical
connector manufacturer’s recommended
procedure.

b) Aluminum/copper connection must

conform with local codes and industry-
accepted wiring practices.

Copies of the standards listed may be obtained
from:

* National Fire Protection Association

One Batterymarch Park
Quincy, Massachusetts 02269

** CSA International

8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575

If codes permit and a separate ground
wire is used, it is recommended that a
qualified electrician determine that the
ground path and wire gauge are in
accordance with local codes.
Do not ground to a gas pipe.
Check with a qualified electrician if you
are not sure the range is properly
grounded.
Do not have a fuse in the neutral or
ground circuit.
This range must be connected to a
grounded metal, permanent wiring
system.

A.

A four-wire or three-wire, single

phase, 240-volt, 60-Hz, AC-only electrical
supply is required on a separate, 30-
ampere circuit, fused on both sides of the
line. A time-delay fuse or circuit breaker is
recommended. The fuse size must not
exceed the circuit rating of the range
specified on the model/serial rating plate
located on the horizontal surface below
the control panel.

B.

Wire sizes and connections must

conform to the requirements of the
National Electrical Code ANSI/NFPA 70 –
latest edition*, or CSA Standards C22.1-
94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 - latest edition** and all
local codes and ordinances.

C.

The range should be connected

directly to the fused disconnect or circuit
breaker box through flexible, armored or
non-metallic sheathed, copper cable. The
flexible, armored cable extending from the
fuse box or circuit breaker box should be
connected directly to the junction box.

D.

Locate the junction box to allow

as much slack as possible between the
junction box and the range so that the
range can be moved if servicing is ever
necessary. Do not cut the conduit.

E.

A U.L.- or CSA-listed conduit

connector must be provided at each end
of the power supply cable (at the cooktop
and at the junction box).

Installation

Excessive Weight Hazard

Use two or more people to move
and install range.

Failure to do so can result in back
or other injury.

WARNING

1.

Put on safety glasses and gloves.

Remove shipping materials, tape and
protective film from range. Keep shipping
pallet under range. Unpack the burner
grates, burner caps, simmer plate, grille
grate, drip tray, spill guard, wave tray,
wave plate, tile bezels, regulator,
backguard and island trim. Items are
either packaged in the range or on the
range. Parts shipped with range depend
on model ordered.

2.

Remove the bottom vent by

removing the 2 screws on each side of
the top of the bottom vent, Slide the vent

3.

Lay a piece of cardboard from side

packing on the floor behind range. Using
2 people, firmly grasp each side of range.
Lift range up about 3 inches (8 cm) and
move it back until the range is off
shipping pallet. Set range on cardboard to
avoid damaging floor.

5.

Choose the correct bracket for your

installation.

• If the wall behind the range has no

baseboard or a baseboard up to 3/8"
(9.5 mm) thick, use the shorter 1"
(2.5 cm) anti-tip bracket.

• If the wall behind the range has a

baseboard thicker than 3/8" (9.5 mm),
use the longer 1-3/4" (4.4 cm) anti-tip
bracket.

Locate a stud in wall behind range.
Measure distance from top of rear brace
to floor. Add 5/16" (7.9 mm) to
measurement to allow anti-tip bracket to
slide over rear brace. Use this final
measurement and mark a horizontal line
on wall where stud is located.

write down
this distance

rear
brace

down and pull toward you. Carefully lay
this part to the side to avoid scratching
the stainless steel.

Summary of Contents for 8301169

Page 1: ...uestions regarding features operation performance parts or service Call 1 800 422 1230 or visit our web site at www kitchenaid com IMPORTANT Read and save these instructions 36 91 4 cm Commercial Style Dual Fuel Range with self cleaning thermal convection oven for residential use only OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF backguard required for some installations For the ...

Page 2: ...e below the control panel This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas Code ANSI Z223 1 latest edition or CAN CGA B149 latest edition installation codes WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damag...

Page 3: ...ons or other installations with more than 5 12 7 cm clearance to back wall use the optional stainless steel island trim included with the range to cover the backguard mounting flanges 36 91 4 cm min upper cabinet width 36 1 4 92 1 cm opening width 20 50 8 cm 12 30 5 cm 5 1 2 14 cm 8 20 3 cm 18 45 7 cm upper cabinet to countertop gas line opening to be located in this area junction box to be locate...

Page 4: ...n the same room but external to the range and should be in a location that allows ease of opening and closing Do not block access to the shutoff valve gas supply line shutoff valve open position G If rigid pipe is used as a gas supply line a combination of pipe fittings must be used to obtain an in line connection to the range All strains must be removed from the supply and fuel lines so range wil...

Page 5: ...ition and all local codes and ordinances C The range should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable The flexible armored cable extending from the fuse box or circuit breaker box should be connected directly to the junction box D Locate the junction box to allow as much slack as possible between the junction...

Page 6: ...ermit connecting the frame ground conductor to the neutral white junction box wire not used for Canadian installations Figure 2 Grounded neutral junction box red wires white wire white and bare grounding oven cable wires factory crimped 3 wire cable from power supply black wires 4 wire cable from range U L or CSA listed conduit connector 1 Disconnect power supply 2 Connect the flexible armored cab...

Page 7: ...heck connections again Clean all detergent solution from range 14 Put a burner cap on each burner base Place burner grates over burner bases and caps If your model has only surface burners no grille or griddle go to Check the operation of the surface burners grille and griddle on Page 9 If your model was shipped with a grille or griddle go to Installing the grille or griddle on Page 8 to complete ...

Page 8: ...the slot in the left rear corner of the wave tray H Place the wave plate on the wave tray as shown The wave plate must be centered on the wave tray E Plug power supply cord into grounded outlet C Plug power supply cord into grounded outlet I Install the grille grate A Place drip tray in the well at the front of the griddle Slide tray forward until it stops B Refer to the Use and Care Guide that ca...

Page 9: ... from HI to LO position without extinguishing the flame Flame should be as small as possible without going out ports typical surface burner flame at highest setting 18 Electronic Ignition System initial lighting Surface burners use electronic ignitors in place of standing pilots When the cooktop control knob is pushed in and turned to the LITE position the system creates a spark to light the burne...

Page 10: ...uld need service call the dealer from whom you purchased the appliance or a KitchenAid designated service company A KitchenAid designated service company is listed in the Yellow Pages of your telephone directory under Appliances Household Major Service and Repair You can also obtain the service company s name and number by dialing free within the continental United States the KitchenAid Customer I...

Page 11: ...R LATCH R V P7 5 SUPPRESSOR WP 4451985 ELECTRONIC CONTROL DOUBLE LINE BREAK RELAY TOD NON RESETABLE P9 1 P9 3 WISP CONNECTOR SEE BLOWER REMAINS OFF UNTIL OVEN REACHES 190 F 88 C AND MAY CONTINUE RUNNING UP TO 45 MINUTES AFTER OVEN HAS TURNED OFF LATCH ASSY F Y ORG 2 1 A BK W BK BK BK OFF AUTO LIGHT SWITCH LIGHT POWER SUPPLY BU BU P3 2 P3 3 BK Y P8 1 P8 3 Y P8 2 ORG P8 4 BK DOOR SWITCH 2 ON LATCH A...

Page 12: ...Part No 8301169 Rev A 2003 KitchenAid Registered Trademark Trademark of KitchenAid U S A KitchenAid Canada licensee in Canada Prepared by KitchenAid Benton Harbor Michigan 49022 Printed in U S A ...

Page 13: ...r au 1 800 422 1230 ou consulter notre site Internet à l adresse www kitchenaid com IMPORTANT Lire et conserver ces instructions Cuisinière style commercial 91 4 cm 36 po deux combustibles avec four autonettoyant thermique à convection pour utilisation résidentielle seulement OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF OFF Dosseret nécessaire pour certaines configurations d install...

Page 14: ...ue signalétique et l étiquette d information sur les gaz combustibles sous le tableau de commande de l appareil L installation réalisée selon ces instructions doit être conforme aux dispositions des codes et règlements locaux En l absence d un code local l installation doit être conforme aux dispositions de la plus récente édition de la norme American National Standard National Fuel Gas Code ANSI ...

Page 15: ...cm 8 po 45 7 cm 18 po entre placard mural et plan de travail Placer la canalisation de gaz dans cette zone Placer la boîte de connexion dans cette zone Dégagement de séparation de 4 po 10 2 cm min entre la cuisinière et un mur des matériaux combustibles des deux côtés de la cuisinière et au dessus de la surface de cuisson Dégagement de séparation de 0 po 0 cm entre les deux côtés et l arrière de l...

Page 16: ...e de gaz devra comporter un robinet d arrêt homologué Ce robinet d arrêt devrait être situé dans la même pièce que la cuisinière à un emplacement permettant un accès aisé pour les manoeuvres d ouverture et de fermeture Ne pas entraver l accès au robinet d arrêt canalisation d arrivée de gaz robinet d arrêt ouvert G Si la canalisation de gaz est une tuyauterie rigide utiliser une combinaison de rac...

Page 17: ... installation en îlot Ces articles emballés peuvent être placés dans la cuisinière ou sur la cuisinière La liste des pièces fournies avec la cuisinière dépend du modèle commandé 3 Placer sur le sol derrière la cuisinière un morceau de carton provenant du côté de l emballage Saisir fermement la cuisinière de chaque côté participation de deux personnes Soulever la cuisinière d environ 8 cm 3 po et t...

Page 18: ...on du circuit 2 Faire passer dans la boîte de connexion à travers un connecteur de conduit homologation UL ou CSA le câble blindé flexible provenant de la cuisinière Serrer les vis sur le connecteur de conduit 3 Avec des connecteurs de fils voir la Figure 1 connecter ensemble les deux conducteurs noirs et les deux conducteurs rouges 4 Séparer le conducteur nu et le conducteur blanc du câble de la ...

Page 19: ...re quelques minutes pour que le gaz expulse l air de la canalisation installation du dosseret installation de la garniture pour îlot trou central pas utilisé 3 vis avant 4 vis nécessaires à l arrière mais pas représentées appliquer un produit d étanchéité conduit de raccordement flexible raccord droit 1 2 po robinet d arrêt manuel canalisation de gaz 1 2 po à 3 4 po un filetage mâle de 1 2 po est ...

Page 20: ...e d utilisation et d entretien fourni avec la table de cuisson au sujet de la préparation de la plaque à frire avant la première utilisation et au sujet du nettoyage C Brancher le cordon d alimentation sur une prise de courant reliée à la terre D Contrôler les flammes des brûleurs standard et du brûleur de la plaque à frire Avant de terminer l installation du gril voir à la page 8 Contrôle du fonc...

Page 21: ...er en 30 à 40 secondes NOTE la flamme du brûleur de la plaque à frire n est pas visible mais on doit percevoir le son émis lors de l allumage et l échauffement de la plaque Après l allumage de chaque brûleur ramener le bouton de commande à la position d arrêt OFF Si un brûleur ne s allume pas correctement ramener le bouton de commande à la position d arrêt OFF Déterminer si le chapeau de brûleur e...

Page 22: ...n peut également téléphoner sans frais au Centre d assistance à la clientèle de KitchenAid au 1 800 422 1230 états continentaux des États Unis un opérateur spécialisé pourra alors communiquer le nom et l adresse du plus proche établissement de service après vente agréé KitchenAid Pour préserver la qualité incorporée dans cet appareil ménager KitchenAid confier les travaux à un établissement de ser...

Page 23: ... 120 V CA 60 HZ MONOPHASE 15 OU 20 A N BL ALLUMEUR DU GRIL CONTACTEUR ROBINET DU GRIL ÉLECTRODES D ALLUMAGE TABLE DE CUISSON N N N BL N BL L1 NEU BL N TERRE VERT BL BL MODULE D ETINCELAGE ÉLECTROVANNE DE LA PLAQUE À FRIRE 120 V CA 60 HZ MONOPHASE 15 OU 20 A N N BL L N G JAUNE OU MARRON 4 PLCS CONTACTEURS ROBINETS DES BRÛLEURS DE LA TABLE DE CUISSON THERMOSTAT DE LA PLAQUE À FRIRE N BL ÉLECTRODES A...

Page 24: ... P7 1 BL BL TAN TAN BL N BL R VENTILATEUR VOIR VERROUILLAGE PORTE MOTEUR DU LOQUET R V P7 5 DISPOSITIF ANTIPARASITE WP no 4451985 COMMANDE ÉLECTRONIQUE RELAIS DISJONCTEUR DEUX LIGNES T O D PAS RÉINITIALISABLE P9 1 P9 3 CONNECTEUR WISP LE VENTILATEUR RESTE ÉTEINT JUSQU À CE QUE LE FOUR ATTEIGNE 19O F 88 C ET PEUT CONTINUER DE FONCTIONNER JUSQU À 45 MINUTES APRÈS QUE LE FOUR EST ÉTEINT SYST DE VERRO...

Reviews: