5
■
Burner assembly (on grill models)
■
Grease trays (2) (on grill models)
■
Griddle drip tray (on griddle models)
■
Grill drip tray (on grill models)
■
Island trim
■
LP orifice package (W10393255)
■
Conversion label (W10393342)
NOTE: The cooktop is manufactured for use with Natural gas.
To convert to LP gas, see the “LP Gas Conversion” section.
Additional Parts Supplied on Steam-Assist Models
■
Model W10049700 water filter kit
■
¼" to ¼" water supply union
Parts needed
■
Power supply cord kit:
■
30" (76.2 cm) and 36" (91.4 cm) models - A UL listed
40 amp power supply cord kit
■
48" (121.9 cm) models - A UL listed 50 amp power supply
cord kit marked for use with nominal 1
³⁄₈
" (34.93 mm)
diameter connection openings
■
A UL listed strain relief
■
UL listed wire connectors
■
All models must be installed with a backguard if installing at
zero clearance to a combustible backwall. See “Cabinet
Dimensions” in the “Location Requirements” section for
installation requirements.
■
30" (76.2 cm) Adjustable Backguard
Order Part Number 8285148
■
36" (91.4 cm) Adjustable Backguard
Order Part Number 8284756
■
48" (121.9 cm) Adjustable Backguard
Order Part Number 8284755
■
9" (22.9 cm) Backguard for 30" (76.2 cm) Ranges
Order Part Number W10115773
■
9" (22.9 cm) Backguard for 36" (91.4 cm) Ranges
Order Part Number W10115776
■
9" (22.9 cm) Backguard for 48" (121.9 cm) Ranges
Order Part Number W10115777
■
22" (55.9 cm) Backguard with Shelf for 30" (76.2 cm)
Ranges
Order Part Number W10225950
■
22" (55.9 cm) Backguard with Shelf for 36" (91.4 cm)
Ranges
Order Part Number W10225949
■
22" (55.9 cm) Backguard with Shelf for 48" (121.9 cm)
Ranges
Order Part Number W10225948
To order, see the “Assistance or Service” section of the Use
and Care Guide.
Additional Parts Needed on Steam-Assist Models
■
Tubing staples/retainers
■
¼" O.D. flexible codes approved water supply tubing (to
make water connection)
■
Water connection device (to connect ¼" O.D. tubing to
water source). Check local codes for type of connection
required.
Check local codes and consult gas supplier. Check existing gas
supply and electrical supply. See “Electrical Requirements” and
“Gas Supply Requirements” sections.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
High Altitude Conversion
To convert the cooktop for elevations above 6,560 ft (1999.5 m),
order a High Altitude Conversion Kit.
■
Part Number W10394296 - LP high altitude
■
Part Number W10394295 - Natural gas high altitude
To order, see the “Assistance or Service” section of the Use and
Care Guide.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances. Do
not obstruct flow of combustion and ventilation air.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial rating plate. The
model/serial rating plate is located on the right vertical
surface of the oven door frame.
■
It is recommended that a 600 CFM or larger range hood be
installed above the range.
■
It is not recommended that a microwave hood combination
be mounted above the range.
■
Recessed installations must provide complete enclosure of
the sides and rear of the range.
■
To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided. If cabinet storage is to be
provided, the risk can be reduced by installing a range hood
that projects horizontally a minimum of 5" (12.7 cm) beyond
the bottom of the cabinets.
■
All openings in the wall or floor where range is to be installed
must be sealed.
■
Do not seal the range to the side cabinets.
■
Cabinet opening dimensions that are shown must be used.
Given dimensions are minimum clearances.
■
The anti-tip bracket must be installed. To install the anti-tip
bracket shipped with the range, see “Install Anti-Tip Bracket”
section.
■
Grounded electrical supply is required. See “Electrical
Requirements” section.
■
Proper gas supply connection must be available. See “Gas
Supply Requirements” section.
■
Contact a qualified floor covering installer to check that the
floor covering can withstand at least 200°F (93°C). Use an
insulated pad or ¼" (0.64 cm) plywood over carpet and under
range if installing range over carpeting.
IMPORTANT: To avoid damage to your cabinets, check with your
builder or cabinet supplier to make sure that the materials used
will not discolor, delaminate or sustain other damage. This oven
has been designed in accordance with the requirements of UL
and CSA International and complies with the maximum allowable
wood cabinet temperatures of 194° (90°C).