12
2. Determine and mark centerline of the cutout space. The
mounting bracket must be installed on the right side of the
cutout. Position mounting bracket in cutout as shown in the
following illustration.
Measurement B:
30" (76.2 cm) ranges: 11
⁵⁄₈
" (29.5 cm)
36" (91.4 cm) ranges: 14
⁵⁄₈
" (37.1 cm)
48" (121.9 cm) ranges: 20
⁵⁄₈
" (52.4 cm)
Measurement C:
Optional distance from back wall. If back wall is constructed
of a combustible material and a backguard is not installed, a
6" (15.2 cm) minimum clearance is required for all models.
Install anti-tip bracket accordingly.
3. Drill two
¹⁄₈
" (3.0 mm) holes that correspond to the bracket
holes of the determined mounting method. See the following
illustrations.
Floor Mounting
Wall Mounting
4. Using a Phillips screwdriver, mount anti-tip bracket to the wall
or floor with the two #12 x 1
⁵⁄₈
" screws provided.
Depending on the thickness of your flooring, longer screws
may be necessary to anchor the bracket to the subfloor.
Longer screws are available from your local hardware store.
5. Move range close enough to opening to allow for electrical
connections to be made. Remove shipping base, cardboard
or hardboard from under range.
6. Continue installing your range using the following installation
instructions.
A. Centerline
B. Centerline of cutout to centerline of anti-tip bracket
C. Back wall to back of range
A
B
C
A. #12 x 1
⁵⁄₈
" screws
B. Anti-tip bracket
A. #12 x 1
⁵⁄₈
" screws
B. Anti-tip bracket
B
A
B
A