0
OPERATION
This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.
kitchenbrains.com
Page 7 of 16
© 2020 Kitchen Brains
Timed with Auto Panic–
T
his feature requires the Magnetic
contacts, IP-1 and/or MD-1/MD-1+2 installed.
OPERATION:
• When the door is open
ed,
lights will be
turned on.
• When the door is closed the lights-off
timer
will be activated and the IP-1 shall start to
beep and blink for 40 seconds to prompt a
“check-in” by pressing the IP-1 button. If
within the 40 seconds the IP-1 button is not
pressed, the light will turn off.
PRESSING THE IP-1 BUTTON
WILL DO THE FOLLOWING:
• Stop the lights-off timer
and keep the lights on indefinitely - for
as long as the door remains closed. Start a 20-minute Auto Panic
timer.
• “Lock out”
the light Switch on the 75LCT. This feature prevents
someone outside the Cooler/Freezer from turning off the light
when the Cooler/Freezer is occupied.
• After 20 minutes, I
P-1 starts to beep and blink again for 40 seconds
to prompt a “check in” button press. Pressing the IP-1 resets and
restarts Auto Panic timer. This cycle will repeat for as long as
someone remains in the Cooler/Freezer with the door closed. If
IP-1 isn’t pressed within 40 seconds of beeping & blinking, the
75LCT will automatically sound a panic alarm.
• Opening and closing the door
will reset all functions. If no one is in
the Cooler/Freeezer to press the IP-1 after door is closed, light will
turn off when lights-off timer expires.
NOTE 1
:
when both the Magnetic contacts and IP-1 are installed,
the IP-1 will only be able to turn the Lights On when the door is
closed; when door is open, IP-1 shall be able to either turn the Lights
On or Off.
NOTE 2:
With the door closed, the IP-1 shall blink and beep for 40
seconds before the lights-off timer expires. Pressing the IP-1 at any
time shall always activate the 20-minute Auto Panic timer.
NOTE 3:
If door is closed and lights are off, the IP-1 shall work as
a “lights on” switch inside of the walk-in and activate the 20-minute
Auto Panic timer when pressed.
NOTE 4:
The MD-1/MD-1+2 motion detector may be used in lieu of
or with the IP-1. The MD-1/MD-1+2, when activated by motion shall
duplicate an IP-1 press and automate the process.
UNTIMED MANUAL ON-OFF LIGHT CONTROL
OPERATION:
Without accessories –
Pressing light button on the 75LCT shall turn
lights on. Pressing again shall turn lights off.
With IP-1 installed –
IP-1 shall act as a “lights ON/OFF” switch from
inside of the walk-in.
With Magnetic Contacts installed –
Lights will turn On when the
door is open.
With MD-1/MD-1+2 installed:
Lights will be activated by movement
of personnel in the Cooler/Freezer and keep them On indefinitely for
the duration of their stay (as long as motion is sensed).
75LCT CONFIGURATION MODE:
In the Setup/Configuration mode, the Main menu provides the
following options:
View Settings –
Lists current settings
Program –
Allows users to make changes
to default settings
Sleep –
Disconnects circuit electrically but
not physically
Prev. Maintenance –
Allows users to set
preventive maintenance reminders
Test –
Tests operation of the units and
accessories (screen, relays, LED)
Device Info –
Displays software version
& Product ID
Manuals –
QR code link to KB web User manuals
NOTE:
Run Mode:
Normal operating mode of the 75LCT when AC power is
connected to the unit and the 75LCT is not in any of the above Main
Menu selections
Normal operating mode
will be restored after 10 seconds of
inactivity in anyone of the above screens,
except
Sleep & Test.
During Test, pressing the Silence logo will return device to normal
operating mode.
75LCT MULTI-MONITOR |
OPERATING MANUAL