Timed with Auto Panic– 

T

his feature requires the Magnetic 

contacts, IP-1 and/or MD-1/MD-1+2 installed.

OPERATION:

•  When the door is open

ed, 

lights will be 

turned on. 

•  When the door is closed the lights-off

 timer 

will be activated and the IP-1 shall start to  

beep and blink for 40 seconds to prompt a  

“check-in” by pressing the IP-1 button. If  

within the 40 seconds the IP-1 button is not 

pressed, the light will turn off.

PRESSING THE IP-1 BUTTON  

WILL DO THE FOLLOWING: 

•  Stop the lights-off timer 

and keep the lights on indefinitely - for 

as long as the door remains closed. Start a 20-minute Auto Panic 

timer. 

•   “Lock  out” 

the light Switch on the 75LCT. This feature prevents 

someone outside the Cooler/Freezer from turning off the light 

when the Cooler/Freezer is occupied. 

•  After 20 minutes, I

P-1 starts to beep and blink again for 40 seconds 

to prompt a “check in” button press. Pressing the IP-1 resets and 

restarts Auto Panic timer. This cycle will repeat for as long as 

someone remains in the Cooler/Freezer with the door closed. If 

IP-1 isn’t pressed within 40 seconds of beeping & blinking, the 

75LCT will automatically sound a panic alarm.

•  Opening and closing the door

 will reset all functions. If no one is in 

the Cooler/Freeezer to press the IP-1 after door is closed, light will 

turn off when lights-off timer expires.

NOTE 1

when both the Magnetic contacts and IP-1 are installed, 

the IP-1 will only be able to turn the Lights On when the door is 

closed; when door is open, IP-1 shall be able to either turn the Lights 

On or Off.

NOTE 2:

 

With the door closed, the IP-1 shall blink and beep for 40 

seconds before the lights-off timer expires. Pressing the IP-1 at any 

time shall always activate the 20-minute Auto Panic timer. 

NOTE 3:

 

If door is closed and lights are off, the IP-1 shall work as 

a “lights on” switch inside of the walk-in and activate the 20-minute 

Auto Panic timer when pressed. 

NOTE 4:

 

The MD-1/MD-1+2 motion detector may be used in lieu of 

or with the IP-1. The MD-1/MD-1+2, when activated by motion shall 

duplicate an IP-1 press and automate the process.

UNTIMED MANUAL ON-OFF LIGHT CONTROL 

OPERATION: 

Without accessories – 

Pressing light button on the 75LCT shall turn 

lights on. Pressing again shall turn lights off. 

With IP-1 installed – 

IP-1 shall act as a “lights ON/OFF” switch from 

inside of the walk-in. 

With Magnetic Contacts installed – 

Lights will turn On when the 

door is open.

With MD-1/MD-1+2 installed: 

Lights will  be activated by movement 

of personnel in the Cooler/Freezer and keep them On indefinitely for 

the duration of their stay (as long as motion is sensed).

75LCT CONFIGURATION MODE:

In the Setup/Configuration mode, the Main menu provides the 

following options:

View Settings –

 Lists current settings

Program – 

Allows users to make changes 

to default settings

Sleep – 

Disconnects circuit electrically but  

not physically

Prev. Maintenance – 

Allows users to set  

preventive maintenance reminders

Test – 

Tests operation of the units and  

accessories (screen, relays, LED)

Device Info – 

Displays software version  

& Product ID

Manuals – 

QR code link to KB web User manuals

NOTE: 

Run Mode: 

Normal operating mode of the 75LCT when AC power is 

connected to the unit and the 75LCT is not in any of the above Main 

Menu selections

Normal operating mode 

will be restored after 10 seconds of 

inactivity in anyone of the above screens, 

except 

Sleep & Test. 

During Test, pressing the Silence logo will return device to normal 

operating mode.

75LCT MULTI-MONITOR  |  

OPERATING MANUAL

Summary of Contents for Modularm 75LCT

Page 1: ...0 75LCT MULTI MONITOR OPERATING MANUAL SAVE THESE INSTRUCTION FOR FUTURE REFERENCE kitchenbrains com 24 7 Toll Free Technical Support 1 800 243 9271 From the U S Canada and the Caribbean...

Page 2: ...utton Panic Entrapment Alarm is an optional accessory that provides light control panic and auto panic inside the compartment Works with the DAC 55 DL 35 75LC and Datalarm Entrapment Alarms Panic Alar...

Page 3: ...ctions with easy programming and operation OVERVIEW 75LCT FUNCTIONS The 75LCT offers the following functions Patented Operation 2 Autodetect accessories 3 AC Failure Alarm with built in rechargeable b...

Page 4: ...IP 1isavailable to be installed inside the Cooler Freezer and provides the ability to control the light within the Cooler Freezer as well as a mechanism to sound a panic alarm press the IP 1 to turn o...

Page 5: ...rohibited kitchenbrains com Page 5 of 16 2020Kitchen Brains PANIC ALARM Non Applicable DOOR AJAR Door Icon On Door Ajar Message Light Icon On Audible Alarm TABLE 1 Status of the 75LCT for Abnormal Ala...

Page 6: ...he Cooler Freezer Auto Panic can be cleared by either pressing the Control Icon Silence Icon displayed on the 75LCT screen or by opening and closing the door for those installations that have the MC 1...

Page 7: ...urn the Lights On or Off NOTE 2 With the door closed the IP 1 shall blink and beep for 40 seconds before the lights off timer expires Pressing the IP 1 at any time shall always activate the 20 minute...

Page 8: ...ure alarm condition Alarm Relay Mode Set mode of operation for relay Auto Panic Set auto panic mode PROGRAM Allows user to configure change default parameters Table 2 lists the default settings as wel...

Page 9: ...hold until the screen reads Powering Off 2 All functions are shut off 3 The battery automatically reconnects electrically the next time AC Power is applied RUN MODE All 75LCT monitoring functions take...

Page 10: ...OF INACTIVITY Probe Calibration The 75LCT comes pre calibrated to read proper temperature with Automatic Scale Conversion from F to C Calibration parameter provides a means for offsetting the display...

Page 11: ...tely rated wire insulation type voltage rating and wire gauge for all connections Supply connection wiring must be rated at least 90 C Use copper conductors only The enclosure used for mounting the Pr...

Page 12: ...the door There is no need to open or access the motion detector itself Mount the MD 1 MD 1 2 horizontally with the white oval lens facing down The red light inside of the MD 1 MD 1 2 will illuminate...

Page 13: ...ilized to assist in proper switch and magnet placement NOTE For compartments with more than one door multiple sets of contacts wired in series may be utilized to monitor multiple door s status Mountin...

Page 14: ...ion copying or duplication of this document or software described herein without prior written authorization is strictly prohibited kitchenbrains com Page 14 of 16 2020Kitchen Brains 75LCT STANDARD AC...

Page 15: ...ion publication copying or duplication of this document or software described herein without prior written authorization is strictly prohibited kitchenbrains com Page 15of 16 2020Kitchen Brains 75LCT...

Page 16: ...your Evap Monitor your Condenser Monitor your Door Openings Monitor your Temperature Monitor your Walk In s Monitor your Reach In s Kitchen Brains 905 Honeyspot Road Stratford CT 06615 kitchenbrains c...

Reviews: