CONFIGURATION MODE

This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.

kitchenbrains.com

Page 11 of 16

© 2020 Kitchen  Brains

THE TWO RELAY MODES ARE:

Unlatched – 

Default Setting. Relay activates when alarm  

occurs and deactivates when Silence is pressed. Typical  

Application: Controlling a remote buzzer or light. 
  1. Press gear button to access menu

  2. Scroll to unlatched relay mode

  3. Select unlatched

75LCT MULTI-MONITOR  |  

OPERATING MANUAL

Latched – 

Relay activates when alarm occurs and 

 

deactivates when both alarm condition has been cleared and  

Silence has been pressed. Typical Application: Connection to 

a building management system where relay remains activated 

until alarm condition clears and is acknowledged.
  1. Press gear button to access menu

  2. Scroll to latched relay mode

  3. Select latched

INSTALLATION GENERAL SAFETY MEASURES AND PRODUCT LIMITATIONS 

•  This product (“Product”) must be installed by a licensed electrician 

experienced in working in the types of environments for which this 
Product is intended to be utilized; specifically, commercial Cooler/
Freezer coolers and freezers (“Equipment”). 

•  Personnel installing the Product must carefully and completely 

read the Operating and Installation Instructions (“Instructions”), 
and  instructions  and  specifications  of  the  Equipment  manufacturers, 
before attempting to operate and install the Product. Failure  
to comply with the Instructions, and the instructions and 

 

specifications  of  the  Equipment  manufacturers,  may  result  in  
personal injury and/or property damage and may void the 

 

warranty of the Product. Retain the Instructions for 

 

future reference. 

•  The Product shall only be used for the purposes described in  

the Instructions. 

•  During installation of the Product, all applicable laws, regulations 

and industry rules, including local electrical and safety codes, the 
National Electric Code (NEC) and the Occupational Safety and 
 Health Act (OSHA), must be strictly followed. Consistent 

 

therewith, follow applicable electrical codes regarding running of low  
voltage wiring and high voltage wiring in separate conduits and use  
appropriately rated wire (insulation type, voltage rating and wire 
gauge) for all connections. Supply connection wiring must be rated 
at least 90°C. Use copper conductors only. 

•  The enclosure used for mounting the Product must be properly 

grounded according to electrical code. 

•  Confirm that the power source conforms to the requirements of the 

Product before connecting. 

•  Do not exceed the rated limits of the Product. Refer to the Product 

specifications for suitability of the Product to the application. 

•  The Product is not suitable for use in wet locations. Do not expose 

the Product to water, moisture or condensation. In no event should

 

 

the Product be exposed to environments where sudden 
temperature changes with high humidity may result in the 

 

formation of condensation. 

•  Any  openings  in  the  walls,  ceiling  or  floor  of  the  Equipment 

for wiring or other reason must be sealed (made airtight and  
watertight) with appropriate materials (e.g., silicone, caulk or 
foam), both on the outside and inside of the Equipment, to prevent 
moisture or condensation from entering the compartment of the 
Equipment and forming and accumulating on the interior walls of 
the compartment and the contents of the compartment, including 
the Product. Failure to properly seal such openings may (i) result 
in damage to the Equipment and contents of the compartment 
(ii) pose a safety hazard and (iii) void the warranty of the Product. 

•  To prevent moisture or condensation from entering or forming  

in the enclosure used for the Product, any openings in this  
enclosure (for wiring access or other purpose) must be 

 

appropriately sealed with materials such as silicone, caulk 

 

or foam. 

•  Installation of the Product should be inspected and the Product  

tested  by  qualified  personnel  to  ensure  the  Product  performs 
safely  and  in  accordance  with  the  Product  specifications.  
Periodic testing of the Product should be performed on an  
ongoing basis (at least quarterly) to ensure the Product 

 

continues to perform properly. 

•  All personnel operating, maintaining, repairing or interfacing with 

the Product must be instructed in the use of the Product and  
provided with the Instructions. The Instructions must be kept in an 
accessible location for easy reference. 

• 

 WARNING:

 Hazard of electric shock! Power sources must be 

turned off or otherwise disconnected prior to installation or  
servicing of the Product. Lock and tag power disconnects to  
prevent an unexpected application of power.

Summary of Contents for Modularm 75LCT

Page 1: ...0 75LCT MULTI MONITOR OPERATING MANUAL SAVE THESE INSTRUCTION FOR FUTURE REFERENCE kitchenbrains com 24 7 Toll Free Technical Support 1 800 243 9271 From the U S Canada and the Caribbean...

Page 2: ...utton Panic Entrapment Alarm is an optional accessory that provides light control panic and auto panic inside the compartment Works with the DAC 55 DL 35 75LC and Datalarm Entrapment Alarms Panic Alar...

Page 3: ...ctions with easy programming and operation OVERVIEW 75LCT FUNCTIONS The 75LCT offers the following functions Patented Operation 2 Autodetect accessories 3 AC Failure Alarm with built in rechargeable b...

Page 4: ...IP 1isavailable to be installed inside the Cooler Freezer and provides the ability to control the light within the Cooler Freezer as well as a mechanism to sound a panic alarm press the IP 1 to turn o...

Page 5: ...rohibited kitchenbrains com Page 5 of 16 2020Kitchen Brains PANIC ALARM Non Applicable DOOR AJAR Door Icon On Door Ajar Message Light Icon On Audible Alarm TABLE 1 Status of the 75LCT for Abnormal Ala...

Page 6: ...he Cooler Freezer Auto Panic can be cleared by either pressing the Control Icon Silence Icon displayed on the 75LCT screen or by opening and closing the door for those installations that have the MC 1...

Page 7: ...urn the Lights On or Off NOTE 2 With the door closed the IP 1 shall blink and beep for 40 seconds before the lights off timer expires Pressing the IP 1 at any time shall always activate the 20 minute...

Page 8: ...ure alarm condition Alarm Relay Mode Set mode of operation for relay Auto Panic Set auto panic mode PROGRAM Allows user to configure change default parameters Table 2 lists the default settings as wel...

Page 9: ...hold until the screen reads Powering Off 2 All functions are shut off 3 The battery automatically reconnects electrically the next time AC Power is applied RUN MODE All 75LCT monitoring functions take...

Page 10: ...OF INACTIVITY Probe Calibration The 75LCT comes pre calibrated to read proper temperature with Automatic Scale Conversion from F to C Calibration parameter provides a means for offsetting the display...

Page 11: ...tely rated wire insulation type voltage rating and wire gauge for all connections Supply connection wiring must be rated at least 90 C Use copper conductors only The enclosure used for mounting the Pr...

Page 12: ...the door There is no need to open or access the motion detector itself Mount the MD 1 MD 1 2 horizontally with the white oval lens facing down The red light inside of the MD 1 MD 1 2 will illuminate...

Page 13: ...ilized to assist in proper switch and magnet placement NOTE For compartments with more than one door multiple sets of contacts wired in series may be utilized to monitor multiple door s status Mountin...

Page 14: ...ion copying or duplication of this document or software described herein without prior written authorization is strictly prohibited kitchenbrains com Page 14 of 16 2020Kitchen Brains 75LCT STANDARD AC...

Page 15: ...ion publication copying or duplication of this document or software described herein without prior written authorization is strictly prohibited kitchenbrains com Page 15of 16 2020Kitchen Brains 75LCT...

Page 16: ...your Evap Monitor your Condenser Monitor your Door Openings Monitor your Temperature Monitor your Walk In s Monitor your Reach In s Kitchen Brains 905 Honeyspot Road Stratford CT 06615 kitchenbrains c...

Reviews: