3-Component Force Link, Type 9327C
Page 6
9327C_002-477e-05.10
2.2
Unpacking
Check all packaging for transport damage. Report any such
damage to the transporters and to the authorized Kistler
distributor.
2.3
Notes on Handling the Instrument
The sensor must be used only under the environmental
and operating conditions specified.
With piezoelectric sensors, insulation resistance is of
crucial importance; it must be approx. 10
14
(but not
less than 10
13
). In order to preserve this value, all
plug-and-socket connections must be kept absolutely
clean and dry. The insulation resistance can be meas-
ured with the insulation tester Type 5493.
Protect the connector of the sensor against contamina-
tion and on no account touch it with your fingers (con-
nector front). Fit the cover supplied over the connector
when it is not in use.
A high-insulation cable is used to connect the sensor to
a charge amplifier. Once fitted, it should if possible
remain connected to the sensor. Use only specified con-
necting cables.
Protect the sensor when it is not in use by storing it in
its original packaging.