Technical Data
9327C_002-477e-05.10
Page
33
9.
Technical Data
Please note that all technical data and all additional infor-
mation in this section may be altered at any time without
prior notice
.
9.1
3-Component Force Link Type 9327C
Range
(Without moment loading e.g. when
four force links are mounted in a
force plate)
F
x
, F
y
kN –4
...
4
Range
(Example with force application point
on the surface of the cover plate)
F
x
, F
y
kN –1
...
1
Range
(Force application point centric)
F
z
kN
–8
...
8
Overload F
x
, F
y
, F
z
%
20
Calibrated Range
(Force application point 8 mm
below the surface of the cover plate)
F
x
, F
y
kN
0 ... 1
0 ... 0,1
Calibrated Range
(Force application point centric)
F
z
kN
0 ... 8
0 ... 0,8
Permissible moment load
(M
z
= 0; F
z
= 0)
M
x
, M
y
N·m –22/22
Permissible moment load
(M
x,y
= 0, F
z
= 0)
M
z
N·m
–23/23
Threshold
N
<0,01
F
x
, F
y
pC/N
–7,8
Sensitivity
F
z
pC/N
–3,8
Linearity, each axis
%FSO
0,5
Hysteresis, each axis
%FSO
0,5
F
z
F
x
, F
y
%
1
F
x
F
y
%
3
Crosstalk
(Crosstalk F
x
, F
y
F
z
is
2 %,
when, for example, four force links
are mounted in a dynamometer)
F
x
, F
y
F
z
%
3
fn (x)
kHz
3,2
fn (y)
kHz
3,2
Natural frequency
fn (z)
kHz
12
Operating temperature range
°C
–40
...
120
Insulation resistance at 20 °C
>10
13
Ground insulated
>10
8
Capacitance, each channel
pF
30
Connecting plug
V3
neg.
Weight
g
380