KisanKraft
TM
BATTERY SPRAYER
KK-BBS-212/218/315/318
: www.kisankraft.com
: +91.80. 22178200
Page 16 of 32
TROUBLESHOOTING
Abnormal misting
Problem
Cause
Remedy
The motor does
Not work
The power switch is in “0”
Switch to “
一
“
The plug is lax
Reconnection
The Switch got damaged
Replace the switch
The Line is cut off
Replace the line or
Reconnect it
Fuse got melted
Replace the fuse
The motor is cut out
Replace the motor
The motor is burned to damage
Replace the motor
The voltage of the battery is low
Charge or replace the
battery
High pressure on pipe
Open the handle
Switch
The pressure switch is not
effective
Replace pressure switch
The motor
is running
No spraying
The nozzle got clogged/blocked
Clean the nozzle
No medicine liquid in the tank
Fill chemical
Liquids
The air valve of the chemical tank
lid got clogged
Clean the air valve
Pump valve got clogged
Clean the pump valve
The absorbing filter got jammed
Clean the filter
The nut on the pressure switch is
loose
Tighten the nut
Pump valve got jammed
Clean the pump valve
Pressure spring is not effective
Replace the pressure
spring
The diaphragm is not effective
Replace the diaphragm
The
pressure
does not
increase
Pump valve got clogged
Clean the pump valve
The adjusting valve of pressure
got jammed
Clean the valve
Inlet nozzle on the tank lid got
jammed
Clean the nozzle
The motor is abnormal
Replace the motor
Spout wear
Replace
The pressure switch is not
effective
Replace the pressure
switch