Page 15
No AC output.
Status LED is
Green
Circuit Breaker is tripped
Check load and reset the breaker
No Output.
Status LED is
in Amber
Circuit Breaker is tripped
Check error code on display
Check AC Load Sense setting
Check load and reset the breaker
Verify the error condition and make
correction
AC Load connected must be below the
threshold of the AC Load sense setting
7. SPECIFICATIONS
Note: Specifications are subject to change without notices.
120V model
230V model
Specification
SWXFR
1210
(1000W)
SWXFR
1220
(2000W)
SWXFR
1230
(3000W)
SWXFR
1210i
Series
(1000W)
SWXFR
1220i
Series
(2000W)
Inverter
AC Output Power
1000W
2000W
3000W
1000W
2000W
AC Output Current
8.3A
16.6A
25.0A
4.3A
8.7A
AC Surge Power (Peak)
2000W
4000W
6000W
2000W
4000W
AC Output Voltage/Frequency
120VAC / 60 Hz
230 VAC / 50 Hz
AC Output Waveform
Sinewave (<3% THD)
Nominal DC Input Voltage
12.5 VDC
No Load battery draw
< 1.5 ADC
DC Input Voltage operating
range
10.5 – 15.5 VDC
Under Voltage Alarm
11.0/12.1 VDC
Under Voltage Alarm
Recovery
11.3/12.3 VDC
Under Voltage Shutdown
10.5/11.8 VDC
Under Voltage Recovery
12.0/12.6 VDC
Over Voltage Shutdown
15.5 VDC
USB
USB Port
5V, 750 mA
AC Transfer Switch
Transfer Time
< 30 ms
Transfer Relay Rating
30A
16A
AC Input Source Setting
15, 20, 30A
8, 10, 16A
AC Output Port (AC Socket)
15A max
20A max
20A max
16A max
AC Output Port (Hard Wire)
30A max
30A max
30A max
16A max
AC Output Port (Hard Wire)
15A max
20A max
20A max
Not Applicable
Display
Display Panel Port
RJ12 (6 pins)
Inverter Mode
Input Voltage, Output Power
Safety and Environmental
Conformance
UL458, CSA C22.2 No.107.1
EN/IEC 62040-1&
IEC 61558-2-16
EMI / EMC
FCC part15, Subpart B, Class B
EN/IEC 62040-2
category C1
Agency Markings
cETLus
CE
Operating Temperature
0°C to 40°C (32°F to 104°F)
Storage Temperature
-20°C to 60°C (-4°F to 140°F)