6.2.21 Fit pump half coupling.
6.2.22 Rotate the shaft by hand and ensure free rotation.
6.2.23 Fit all the accessories such as sealing water, flushing water, etc.
6.2.24 Fit the support foot (251) to bearing housing.
6.2.25 Fit the coupling spacer between pump half and motor half coupling in case of spacer
type flexible coupling.
6.2.26 Mount the motor on the base in case of standard flexible coupling and along the unit.