12
© MMXXI Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 210607001
Bent Tube Removal
SuperFlow® 350 Regulator Removal
Installing the 455 Balanced Regulator onto a
SL 17C, SL 27
®
, KM 37 or KM 57 Helmet
Parts Included in the 525-765 Kit:
Part #
Description
Qty
100-100
Warranty Card
1
100-204
Installation Guide, 455 Regulator Kit
1
505-455
455 Balanced Regulator
1
520-042
Tie Wrap
2
VIDEO
How To: Conversion Kit,
455 Regulator for KM 37,
KM 57, SL 17C or SL 27
®
Helmet
https://www.youtube.com/
watch?v=qCucRRcp1fo
1.1 SuperFlow
®
350 Regulator
Removal
Tools Required:
• Socket Wrench
• 1
3/8
" inch socket and/or P/N 525-
625 Regulator Mount Socket Wrench
(Found in 525-620 Tool Kit)
•
3/8
" Drive Extension—Minimum 3" in Length
• #1 Phillips Head Screwdriver
• Open-End Wrench
7/16
" and (2)
7/8
" and
11/16
"
• Slip Joint Pliers and a Cloth
1.1.1 Bent Tube Removal
1. Always start removal at the side block end.
Loosen the tube with the
11/16
inch wrench. The
free swiveling mount nut on this end of the bent
tube can be un-threaded completely and can
slide down the tube.
Always start removal at the side block end.
2. Loosen the lower bent tube nut by using the
two
7/8
inch wrenches. Place one wrench on the
bent tube mount nut and the second on the
regulator inlet jam nut.
Turn only the outer nut
on the bent tube to loosen the bent tube.
3. With the two mount nuts free; the bent tube
assembly can be pulled straight out and away
from the regulator. The bent tube assembly
can be rotated back and forth to aid removal, if
necessary.