Kipp & Zonen METEON Instruction Manual Download Page 6

  

 

METEON window 

 

 

 
All other functions related to the METEON are available in special windows, which will only 
open once you connect an METEON to USB interface cable to the PC. You can connect more 
than one of these interface cables to your PC, and for each of the interfaces a separate 
window will open. These windows may be on top of each other, move them around on your 
screen to reveal the ones that are covered. 
 
 
When the PC cannot find a METEON connected to the cable, the caption of the window will 
be ‘Nothing connected’. To connect a METEON, insert the connector from the cable into the 
METEON. The PC will automatically detect the METEON. If the PC does not detect the 
METEON, then check if the METEON is switched on, and check the batteries. 
 
Once the METEON is detected, the caption of the window will show the serial number of the 
METEON that was connected. 
 
When the view data logger status box is activated the actual logger data is visualized. 

-

 Logger 

status: 

o

  the remaining memory (until 3518 samples is reached) 

o

  or memory full 

o

 low 

battery 

o

 idle 

-

 

the remaining interval time until the next sample is stored 

-

 

the actual min. max. and integral value over the chosen interval. 

Programming the sensor sensitivity 

 
The software is used to program the sensor sensitivity into the METEON. If the METEON 
came bundled with a sensor, your supplier may already have programmed the sensitivity of 
this sensor into the METEON. If that is the case, the software you received may not have this 
option. 
 

Summary of Contents for METEON

Page 1: ...Instruction Manual Irradiance Meter METEON...

Page 2: ...our sole responsibility that the products Type Handheld Readout unit Name METEON to which this declaration relates are in conformity with the following standards Imissions EN 50082 1 Group standard Em...

Page 3: ...mV 6 250 1 V Basic accuracy after factory calibration 0 1 Temperature sensitivity 0 5 over the full temperature range Offset drift 3 V over the full temperature range Operation temperature range 10 4...

Page 4: ...f the METEON to avoid damage to the case Extract the battery holder from the compartment and install two fresh batteries Notice the polarization Replace the bottom cover and connect the sensor The MET...

Page 5: ...es bundled with a sensor the sensitivity is already programmed into the METEON In that case the optional interface cable and the software give you access to the data logging functions only Main window...

Page 6: ...the PC does not detect the METEON then check if the METEON is switched on and check the batteries Once the METEON is detected the caption of the window will show the serial number of the METEON that w...

Page 7: ...ftware In the box that says Input amplifier you can select the amplification that corresponds to the required full scale input 2 Next to the amplification factor you can read how many internal counts...

Page 8: ...500 W m2 10 V W m2 CUV 4 200 W m2 1 mV W m2 Use the wizard to select the sensor model that is to be used and then enter the sensitivity of the sensor This is only required when the sensor is changed o...

Page 9: ...one the start of the first logging interval until a specified date and time This date and time at which the first interval will start can be entered in the PC software When the logger is busy counting...

Page 10: ...ew the logger status while the logger is active Reading the status will not interfere with the logging process The status will show what the logger is doing how much time remains in the current interv...

Page 11: ...e bottom right corner of the area of interest When the mouse is released the chart will zoom in on the selected area Drag the mouse from bottom right to top left to zoom out again Save the data in a l...

Page 12: ...hrough USB BAT indicates battery low replace with 2 AA Alkaline types m writing data in METEON memory l logging started 0 5 s interval waiting for initial delay to pass 1 s interval The actual reading...

Page 13: ...nen B V Delftechpark 36 2628 XH Delft P O Box 507 2600 AM Delft The Netherlands T 31 0 15 2755 210 info kippzonen com www kippzonen com Kipp Zonen Asia Pacific Pte Ltd 10 Ubi Crescent Lobby E 02 93 Ub...

Reviews: