Kipp & Zonen METEON Instruction Manual Download Page 2

  

 
 

Declaration of Conformity 

 
 

According to EC guideline 89/336/EEC 73/23/EEC 

 
 

We 

Kipp & Zonen B.V. 

 Delftechpark 

36 

 

 

 

2628 XH Delft  

 The 

Netherlands

 

 
Declare under our sole responsibility that the products 
 
Type:

 

Handheld Readout unit 

 

 

Name:

 METEON 

 
 
 
to which this declaration relates are in conformity with the following standards 
 
Imissions  

EN 50082-1 

Group standard 

 

 

 
Emissions  

EN 50081-1 

Group standard 

 EN 

55022 

 

 

 
Safety standard  

IEC 1010-1 

 

 

 
Following the provisions of the directive. 

 
 
 
 
 
 

 

 
 
 

 

B.A.H. Dieterink 

President 

KIPP & ZONEN B.V. 

Summary of Contents for METEON

Page 1: ...Instruction Manual Irradiance Meter METEON...

Page 2: ...our sole responsibility that the products Type Handheld Readout unit Name METEON to which this declaration relates are in conformity with the following standards Imissions EN 50082 1 Group standard Em...

Page 3: ...mV 6 250 1 V Basic accuracy after factory calibration 0 1 Temperature sensitivity 0 5 over the full temperature range Offset drift 3 V over the full temperature range Operation temperature range 10 4...

Page 4: ...f the METEON to avoid damage to the case Extract the battery holder from the compartment and install two fresh batteries Notice the polarization Replace the bottom cover and connect the sensor The MET...

Page 5: ...es bundled with a sensor the sensitivity is already programmed into the METEON In that case the optional interface cable and the software give you access to the data logging functions only Main window...

Page 6: ...the PC does not detect the METEON then check if the METEON is switched on and check the batteries Once the METEON is detected the caption of the window will show the serial number of the METEON that w...

Page 7: ...ftware In the box that says Input amplifier you can select the amplification that corresponds to the required full scale input 2 Next to the amplification factor you can read how many internal counts...

Page 8: ...500 W m2 10 V W m2 CUV 4 200 W m2 1 mV W m2 Use the wizard to select the sensor model that is to be used and then enter the sensitivity of the sensor This is only required when the sensor is changed o...

Page 9: ...one the start of the first logging interval until a specified date and time This date and time at which the first interval will start can be entered in the PC software When the logger is busy counting...

Page 10: ...ew the logger status while the logger is active Reading the status will not interfere with the logging process The status will show what the logger is doing how much time remains in the current interv...

Page 11: ...e bottom right corner of the area of interest When the mouse is released the chart will zoom in on the selected area Drag the mouse from bottom right to top left to zoom out again Save the data in a l...

Page 12: ...hrough USB BAT indicates battery low replace with 2 AA Alkaline types m writing data in METEON memory l logging started 0 5 s interval waiting for initial delay to pass 1 s interval The actual reading...

Page 13: ...nen B V Delftechpark 36 2628 XH Delft P O Box 507 2600 AM Delft The Netherlands T 31 0 15 2755 210 info kippzonen com www kippzonen com Kipp Zonen Asia Pacific Pte Ltd 10 Ubi Crescent Lobby E 02 93 Ub...