33
b)
Two-wire connection.
Due to the increased power consumption,
connecting the ecoTOUCH room panel, an
external 5...12 VDC power supply with a
current of min. 500 mA (max. 1,2 A), which
is not standard equipment of the controller.
Two-wire connection of the executive module with the
room panel.
Cross-section area of wires used to
connect room panel should be min.
0,5 mm
2
.
Max. length of wires should not exceed 30 m.
This length may be longer if the wires used
have cross-section area larger than 0,5 mm
2
.
12.18
Connecting of Internet module
The ecoNET300 Web module should be
connected using the ecoLINK2 interface to
the G2 controller socket, according to the
electric scheme. Then enter the menu:
General settings
→
WiFi
and configure the
module connection to the Wi-Fi network.
Configuration of the ecoNET300 module is
described in manual to this device.