Hydraulic schemes
Scheme with a three-way thermostatic actuator to protect the return water temperature
1
: 1
–
boiler, 2
–
controller, 3
–
boiler temperature sensor, 4
–
outside (weather) temperature sensor, 5
–
room
thermostat, 6
–
boiler pump, 7 - three-way thermostatic valve (manually adjustable), 8 - throttle (poppet)
valve, 9
–
HUW pump, 10 - HUW temp. sensor, 11
–
HUW tank, 12
–
burner feeder (stoker), 13
–
burner
fan, 14
–
main fuel feeder
.
RECOMMENDED SETTINGS:
Parameter
Setting
MENU
Preset boiler temp.
75-80
C
Boiler settings
Min. boiler temp.
65
C
Service settings
→
Boiler settings
Boiler inc. by HUW and Mixer
5-20
C
Service settings
→
CH and HUW settings
Boiler room thermostat
eSTER T1
Service settings
→
Boiler settings
1
The presented hydraulic scheme does not replace central heating engineering design and may be used for
information purposes only!