KINTECH ENGINEERING
ORBIT 360 | USER GUIDE
78
Fig. 33.
STATUS screen: Logger Status
The following information is displayed on this screen:
Error code number: shows errors produced in the last 10 minutes recording
period. The code consists of two bytes and it is given in hexadecimal format.
Each of the 16 bits corresponds to one error and the complete error code number
can exhibit more than one error. The logger offers a brief error summary in
addition to the code.
High byte (HB)
Meaning
HB.0
Not used
HB.1
Internal memory contains data
HB.2
GPS error
HB.3
Not used
HB.4
Not used
HB.5
Reboot
HB.6
Aux board error (Modbus TCP, RS485, GPS)