KINTECH ENGINEERING
ORBIT 360 | USER GUIDE
47
Terminal(s)
Parameter
Value Units
Power Input
V
i
max.
Maximum input voltage
36
V
V
i
min.
Minimum input voltage
-40
V
Frequency 1-10
V
i
max.
Maximum input voltage
5
V
V
i
min.
Minimum input voltage
-0.3
V
Analog 1-15
V
i
max.
Maximum input voltage
5
V
V
i
min.
Minimum input voltage
-0.3
V
RS485
V
i
max.
Maximum input voltage
10.5
V
V
i
min.
Minimum input voltage
-10.5
V
Ext. Com
V
i
max.
Maximum input voltage
13.2
V
V
i
min.
Minimum input voltage
-13.2
V
Table 3.
Electrical specifications: inputs
Parameter
Value
Units
Max. operating temperature
70
ºC
Min. operating temperature
-40
ºC
Table 4.
Operating temperature range