12
4.2 Parameter setting
4.2.1 Set IP port
Note: The terminal has a built-in ID number, and the client's IP port can be preset
before delivery. Generally, no parameter setting is required. If you need to modify
the IP, follow the instructions below. The following two methods require the SIM
card to activate the SMS function.
For example, the client's server IP is: 119.23.233.52, and the port number: 6000.
1
For TCP connection, use SMS to write: *88*1119023233052*6000*1#, send it to
the local phone number, the terminal will reply: set ok, then the setting is successful.
2
For UDP connection, write: *88*1119023233052*6000*0#, send it to the local
phone number, the terminal will reply: set ok, then the setting is successful.
After completing the above settings, the terminal can be connected to the server.
Indicator light is always on or flashing in green, and the red light is flashing
slowly,means terminal has been online and located normally. At this time, close the
top cover and tighten the screws,then fix the equipment on the trailer for use.
3P
power plug
Red
:
Positive
Black
:
Negative
4P communication plug
Green+blue
:
Serial communication signal line
Black:Signal ground
Orange
:
5V Power supply
6P I/Oplug
Brown/Blue
:
2 AD input signal lines
Yellow
:
I/O output signal line
Purple/Orange
:
2 I/O input signal line
Summary of Contents for MT36