background image

                                                                                                           

© 2018 M-Labs Technologies                                                                                                   

1

 / 

14

 

 

User Manual 

 

For the 

PM-L 

LTE CAT 1/3G Wireless Tracking Device

 

 

August 2018 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R1.0 

 

Author 

Revision  Changes 

Date 

The  information presented  in this  document  is strictly  confidential  and  contains trade secrets 

and other confidential information that are the exclusive property of M-Labs Technologies   

Summary of Contents for PM-L

Page 1: ...T 1 3G Wireless Tracking Device August 2018 R1 0 Author Revision Changes Date The information presented in this document is strictly confidential and contains trade secrets and other confidential info...

Page 2: ...2018 M Labs Technologies 2 14 1 0 Initial version 2018 Aug 3 1 1 Updated start up banner and edits 2018 Aug 7...

Page 3: ...ures 8 3 1 Basic Software 8 3 2 Remote Update 8 3 3 Auto Execute 8 3 4 Power Modes 9 3 5 Report 9 Report Queuing 9 Ack ed Mode 10 Event Report Format 10 3 6 Reset 10 Context Preservation 10 3 7 Startu...

Page 4: ...r LTE or WCDMA IP connection or through SMS messaging The PM L presents itself over these connections as an enhanced cellular modem with attached functional elements These elements include GPS locatio...

Page 5: ...4 849 RX 869 894 Antenna Internalsingle antenna UIM requirement Support 3FF SIM interrupt mode No Support Hot plug unplug GPS Antenna Dedicate high performance ceramic antenna Power Inputs 12VDC Input...

Page 6: ...external devices This line is 3 3V logic level input or output with transient voltage protection and internal pull up resistor GP1 is intended to use for a Door open sensor LED s Three LED status ind...

Page 7: ...nal battery voltage is measured This value is scaled to span the most significant 8 bits of the A D and consequently covers a scale from 0 to 32Vfor Input Voltage and 0 to 9Vfor internal battery volta...

Page 8: ...tus Power State Watch Dog Supported Reset Soft reset Startup Banner Supported 3 2 Remote Update The PM L supports OTA field upgrades of the resident application An over the air TFTP Trivial File Trans...

Page 9: ...rs a report Those events include Report timer GPIO change IP change Battery threshold Heartbeat Watchdog Power up Motion Detected Any hardware or software reset will return the device to full power mo...

Page 10: ...ledged the next report is attempted This assures that reports are sent and received in order Ack ed mode assures that all reports are received but adds overhead in time and data Report that is not ack...

Page 11: ...Method 4 1 Hardware Test Item Description Baseband Function Test Power Input Test Power Consumption and Current Test Heat Dissipation Test UART Stability Test GPIO Level Test LED Stability Test Drop...

Page 12: ...2018 M Labs Technologies 12 14 UART Test environment 1 Connect PM L to pc with com serial cable 2 Open Terminal tool and send at command 3 Response can be shown at terminal window...

Page 13: ...mits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed...

Page 14: ...eration is subject tothe following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of t...

Reviews: