Kingspan BF BIODISC Installation Manuallines Download Page 9

GL0016P-02 Installation Guidelines for BioDisc

®

 Units BF, BG, NF & NG 

 

 

9

6.2.2. Connect the cable(s) to the appropriate electrical junction(s) in the BioDisc, fitting the glands 

supplied. The cables can be identified by their numbered end connectors which correspond to 
connection points in the BioDisc. The end numbers on the motor/gearbox cable correspond with the 
numbered terminals in the motor/gearbox terminal box. 

 

Connection Point 

Connector Type

End Numbers 

 Motor/Gearbox 

  

Three Phase : 1, 2, 3, Earth 

 

Terminal Box 

 

Single Phase :  1, 3, Earth   

 

 

 

 

Sludge Return  

Pump 

Junction Box fixed 

inside BioDisc Case 

Pin  

L1, N1, Earth 

Loss of Rotation 

Alarm 

Junction Box fixed to 
Motor Support Beam 

Pin  

 

6, 7, Earth 

6.2.3. Ensure that cables inside the BioDisc are securely tied to the structure, clear of the drive 

arrangement and do not present a trip hazard. 

6.2.4.  Units may be supplied with an optional Independent Remote Alarm (used in conjunction with a 

standard Control Panel). This is supplied with a fixing kit. Install in accordance with the installation 
instructions provided. Please note that the Remote Alarm Unit should not be installed more than 100 
metres from the BioDisc and that the interconnecting cable (customer supply) should be laid in a 
separate trench to prevent electrical interference. 

6.2.5. Connect the incoming power supply to the control panel, using suitable cable and current overload 

protection.  (See section 3.11).  Ensure that the panel is securely closed. 

 

 

Full Load Current (Amps) 

 

 BF 

BG 

NF 

NG 

 

240 volt single phase 

1.3 

1.55 

1.3 

1.55 

 

415 

volt 

three 

phase 

0.69 0.67 0.69 0.67 

Sludge return pump 

240 volt single phase only 

N/A 

2.4 

2.4 

2.4 

 

7.0  Ancillary Equipment

 

Ancillary items should be installed in accordance with the Installation Guide supplied e.g. 

Crude Sewage Pump Station, Effluent Pump Station, Effluent Sample Chamber, Grease Trap. 

 

8.0  Start Up

 

8.1.  Refer to the Owners Handbook for details of the Start Up Procedure. 
8.2.  Once the unit has been installed it should be left filled with water. Please switch on the motor, 

following the procedure in the Owners Handbook and leave the unit running, even if there is no 
sewage being fed into the plant. If the unit has been installed with no operational power supply, then 
remove the motor/gearbox unit, and drive chain/belt and store them in a dry or heated environment 
until such time as the unit is ready for permanent operation. 

 
 

 

BioDisc is the registered trademark of Kingspan. 

Motor/Gearbox

 

   Pin

 

Motor

 

Summary of Contents for BF BIODISC

Page 1: ...ith in the control panel housing If additional copies are required contact Kingspan 510030P BF 3 Phase Control Panel Wiring Diagram 510003P BF 3 Phase Alarm Control Panel Wiring Diagram 510017P BF Sin...

Page 2: ...tails on request Should you wish to inspect the operation of the equipment please observe all necessary precautions including those listed below which apply to maintenance procedures BioDisc units con...

Page 3: ...GL0016P 02 Installation Guidelines for BioDisc Units BF BG NF NG 3...

Page 4: ...also inside units particularly if they have been stored on site prior to installation adding weight and increasing instability Check units before lifting and pump out any excess water 2 5 When lifting...

Page 5: ...though not obligatory for an installation of this type RCD protection is suggested as an extra precaution 3 12 Pump stations or any other associated equipment should have a separate power supply 3 13...

Page 6: ...support the installed load but not so much as to prevent subsequent backfill bonding fully to the base 5 4 Ensure that the slab is free of any stones or other material which could damage the unit Low...

Page 7: ...panel Customer Supply Inlet Pipe Control Panel G L 600mm Inlet Invert Add 100mm For Outlet Invert Concrete backfill minimum 150mm thick but to suit specific site conditions Concrete Pea Shingle or oth...

Page 8: ...control panel should be positioned adjacent to the unit so that a It does not interfere with cover removal b It is convenient for the incoming power supply c It cannot be reached by someone standing i...

Page 9: ...han 100 metres from the BioDisc and that the interconnecting cable customer supply should be laid in a separate trench to prevent electrical interference 6 2 5 Connect the incoming power supply to the...