Page 7

ADVANCED 

CONTROLLER

3

4
5

6

7

8

9

10

11

12

13

14

15

16

17

18

System mode off

Room air temperature Area

Time Display Area

Outdoor temperature

Day of the week

Alarm Indicator

System is using home

settings

System is using away

settings
AM or PM indicator for

current time
System is using sleep

settings
Relative humidity

Percentage

Heat Mode

Keypad is locked (no

padlock means unlocked)

Schedule Activated

Celsius

Auxiliary Heat Source

Heat Pump Active

Domestic Hot Water

Advanced Controller /Comfort Module (Hydro box)

screen indicators

In some cases your system may be fitted with 
an advanced controller or a comfort module 
with auxiliary heaters that also houses an 
advanced controller. Normally, the advanced 
controller or comfort module will have been 
configured by your installer and should 
require no user intervention. An exception to 
this may be if the system develops a fault. 

Details of the main screen icons on the 
advanced controller are given on the next 
page. Item 6 shows the Alarm icon. If this 
becomes active please refer to your advanced 
controller manual or comfort module manual 
to access the parameter table and identify the 
fault code.

ADVANCED CONTROLLER /
COMFORT MODULE (HYDRO BOX) 
SCREEN INDICATOR

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE

KINGSPAN HEAT PUMPS

Summary of Contents for AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE

Page 1: ...AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE...

Page 2: ...c hot water It does this in the same way that a fridge extracts heat from its inside It can extract heat from the air even when the outside temperature is as low as 20 C The heat generated can be used...

Page 3: ...fficient heating output to provide these services without any supplementary heating being required You ll find your Aeromax Plus unit close to a wall outside your property It can also be mounted off t...

Page 4: ...he outside air which is then drawn into the unit by the fan through the evaporator fins and expelled through the front grille The evaporator has liquid refrigerant passing through it which is at a con...

Page 5: ...ble room thermostat controls the temperature of the main living area while thermostatic radiator valves control the temperatures of the radiators in other rooms The Aeromax Plus radiator system works...

Page 6: ...water timings given in the tables below allow for the immersion heater to beactivated after the hot water cycle in the morning This will sanitise the tank temperature to between 60 65 C Typical winter...

Page 7: ...rmally takes place for about 4 minutes per hour When defrosting the fan will stop and water vapour may be seen rising from the heat exchanger This is normal and is not a cause for concern SAFETY PRECA...

Page 8: ...In some cases your system may be fitted with an advanced controller or a comfort module with auxiliary heaters that also houses an advanced controller Normally the advanced controller or comfort modul...

Page 9: ...te can take a long time but when it is warm it can supply heat for several hours and only needs topped up Therefore underfloor heating should not be turned off for long periods 3 THE FANS ARE RUNNING...

Page 10: ...ther inverter board error The error code can be identified from the flashing LED on the Diagnostic Indicator using the following table In the case of more than one error the error with the highest pri...

Page 11: ...T APPLY IF 1 The heat pump and associated equipment has been incorrectly sized for the application 2 The heat pump and associated equipment has not been installed and commissioned in complete accordan...

Page 12: ...Wakefield West Yorkshire WF1 5QU T 0845 260 0258 F 0845 260 0259 sales kingspan renewables com www kingspanenviro co uk Portadown Office 180 Gilford Road Portadown Co Armagh BT63 5LF T 028 3836 4444...