The Aeromax Plus heat pump is designed to operate with a standard heating 
time switch and programmable room thermostat, providing space heating or 
DHW according to demand. The unit has two modes of operation: one for space 
heating through underfloor heating or radiators adjustable between 35°C and 
55°C and a second for DHW preset at 60°C.

We recommend that you review the electricity tariffs from all suppliers in your 
area and select one that will give you the optimum economy in relation to your 
lifestyle and heating demand 

Your heating system is controlled by a programmable room thermostat that allows you to 
choose when to have your heating on and what temperature it should be when it is on. A 
time switch allows you to choose when you want to make hot water. The programmable room 
thermostat controls the temperature of the main living area while thermostatic radiator 
valves control the temperatures of the radiators in other rooms.

The Aeromax Plus radiator system works at a lower surface temperature than traditional 
central heating. This means that your radiators will take a little longer to warm up your home 
but will give you a more even comfortable temperature.

Normally your installer will have ensured that your radiators are correctly sized for operation 
with a heat pump.

Your heat pump supplies Domestic Hot Water at between 50ºC - 55ºC. This is stored in the 
special hot water cylinder provided with your heat pump to ensure that you always have hot 
water on tap.

Kingspan recommend that the hot water cylinder thermostat is set between 55/60 degrees C. 
The cylinder immersion heater should be set at 60ºC - 65ºC.

HEATING AND DOMESTIC HOT WATER 
SYSTEM CONTROLS

Page 4

HOW DO I USE IT?

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE

KINGSPAN HEAT PUMPS

Summary of Contents for AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE

Page 1: ...AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE...

Page 2: ...c hot water It does this in the same way that a fridge extracts heat from its inside It can extract heat from the air even when the outside temperature is as low as 20 C The heat generated can be used...

Page 3: ...fficient heating output to provide these services without any supplementary heating being required You ll find your Aeromax Plus unit close to a wall outside your property It can also be mounted off t...

Page 4: ...he outside air which is then drawn into the unit by the fan through the evaporator fins and expelled through the front grille The evaporator has liquid refrigerant passing through it which is at a con...

Page 5: ...ble room thermostat controls the temperature of the main living area while thermostatic radiator valves control the temperatures of the radiators in other rooms The Aeromax Plus radiator system works...

Page 6: ...water timings given in the tables below allow for the immersion heater to beactivated after the hot water cycle in the morning This will sanitise the tank temperature to between 60 65 C Typical winter...

Page 7: ...rmally takes place for about 4 minutes per hour When defrosting the fan will stop and water vapour may be seen rising from the heat exchanger This is normal and is not a cause for concern SAFETY PRECA...

Page 8: ...In some cases your system may be fitted with an advanced controller or a comfort module with auxiliary heaters that also houses an advanced controller Normally the advanced controller or comfort modul...

Page 9: ...te can take a long time but when it is warm it can supply heat for several hours and only needs topped up Therefore underfloor heating should not be turned off for long periods 3 THE FANS ARE RUNNING...

Page 10: ...ther inverter board error The error code can be identified from the flashing LED on the Diagnostic Indicator using the following table In the case of more than one error the error with the highest pri...

Page 11: ...T APPLY IF 1 The heat pump and associated equipment has been incorrectly sized for the application 2 The heat pump and associated equipment has not been installed and commissioned in complete accordan...

Page 12: ...Wakefield West Yorkshire WF1 5QU T 0845 260 0258 F 0845 260 0259 sales kingspan renewables com www kingspanenviro co uk Portadown Office 180 Gilford Road Portadown Co Armagh BT63 5LF T 028 3836 4444...

Reviews: