4
Mobile Home/Manufactured Housing Installation
This Direct Vent System Appliance must be installed in accordance with the manufacturer’s installation instructions and the Manufactured Home
Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installations, Sites,
and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.
THE ZDV3624NB, ZDV3624LPB, ZDV3628N, ZDV3628LP, ZDV3632N and ZDV3632LP MAY BE INSTALLED IN MANUFACTURED
(MOBILE) HOMES AFTER FIRST SALE IN THE USA. IN CANADA THE ZDV3628N, ZDV3628LP, ZDV3632N AND ZDV3632LP
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES.
Please follow the current ANSI/NFPA 70 National Electrical Code in the USA and CAN/CSA C22.1 Canadian National Electrical Code in Canada.
An appliance must be grounded to the steel chassis of the home with 8 ga. copper wire using a serrated or star washer to penetrate paint or protective
coating to insure grounding.
Use carriage bolt at the attachment point (see diagram above) to secure the appliance to the floor.
Warning:
Do not compromise the structural integrity of the manufactured home wall, floor or
ceiling, during installation of appliance or venting.
For required venting components see venting installation in appropriate section of this manual.
Certified for installation in a bedroom or bedsitting room. In Canada must be installed with listed milli volt thermostat. In USA see local codes.
APPLIANCE MUST BE SECURED TO STRUCTURE
USING SUPPLIED NAIL TABS AND OR FASTEN TO
FLOOR
USE EXISTING HOLE OR REMOVE
EXISTING SCREW TO MOUNT GROUND
WIRE
(FAN MOUNT HOLE OR OUTER WRAP SCREW)
GROUND WIRE FROM APPLIANCE
TO STEEL CHASSIS OF MOBILE
HOME. USE 8 GA COPPER WIRE.
SERRATED OR
STAR WASHER