ZCV42 Facing Requirements
Required Non-Combustible Areas
NOTE: ANY MATERIALS COVERING THE FACE OF THE FIREPLACE MUST BE NON-COMBUSTIBLE (i.e. brick,
stone, tile, concrete board).
FIREPLACE WITH SCREEN ONLY (AS SHIPPED) SHOWN HERE.
Refer to
BASIC FINISHING
Sections 1-6 for important finishing details.
Note:
Do not drive excessively long screws into the face of the unit as internal parts may be damaged.
Recommended:
(Not Necessary)
Non-Combustible
42-5/8
” x 44”
This is to allow concrete board
to be screwed to framing if
used.
Recommended
Non-Combustible
(i.e. Concrete
Board) Screwed to
Framing
Recessed Combustible
Wall for TV, etc. (Optional)
Recommended Non-
Combustible
(i.e.
Concrete Board) 42-
5/8” x 44”Screwed to
Framing
34-11
/16”
MIN
34-
11/16”
Fireplace
Opening
ZCV42
Fireplace
Opening
52-
1/2” MIN for NG
64-
1/2” MIN for LP
Plus Rise of 1/4”
Per Foot*
39-1/8
”
MIN
59-
1/2”
MIN
This area can have
a combustible
surface (i.e. hearth)
Refer to
BASIC FINISHING
Sections 1-6
for important finishing details.
19