INSTALLING – Fan Kit
WARNING
Electrical Grounding Instruction - This
appliance is equipped with a three -
pronged (grounding) plug for your
protection against shock hazard and
should be plugged directly into a
properly grounded three-prong
receptacle.
WARNING
A qualified electrician must connect
electrical wiring to junction outlet for
built-in installation.
Follow all codes.
WARNING
Label all wires prior to disconnection
when servicing controls. Wiring errors
can cause improper and dangerous
operation. Verify proper operation and
servicing.
Installation of Optional Fan Kit
Use Part number Z36FK fan assembly. NOTE that
the thermodisc will not be used, bypass these two
wires by stripping the ends and tie together with a
marrette (as shown Fig. 27).
Fan Installation
1. To install fan locate #8 screws in bottom of fireplace Ref A. Fan and fan shield should always be mounted at the end of
the fireplace with the small clearance shield mounted (corner kit peninsula kit & see-through kit)
2. Slide teardrop hole on fan housing over the two #8 screws, slide fan away from screws and release.
Fan Shield installation
1. Slide shield under firebox nearest fan.
2. Install two 1/2” DT screws from inside of firebox into fan shield.
3. If fireplace has been installed with fan shield mounted opposite to the side with clearance shield. It must be removed and
installed on the appropriate side.
Fan shield location
* Caution: Fan shield must be mounted
directly in front of fan.
Alternate
Fan & Shield
location
Suggested Location for 120V
Junction Box for Fan Kit
Suggested Location for 120V
Power Cable
Fan Shield
Clearance Shield
Fan
Ref: A
Ref: A
Optional in unit
variable speed
control location
WALL MOUNTED
VARIABLE SPEED
CONTROL
Figure 25
Figure 26
Figure 27