Automatic Mode is suitable for two-lengths combined cutting, and is
mainly used for sealing in ways, "
工
" or "H" . There are two specific
operation methods as follows:
(1) Method 1
A. Turn on the task "On/Off" in the "Program Setting" interface.
B. Switch to Automatic Mode.
C. Turn on the Sensor Mode.
D. Press "Start".
E. Reach out to the sensing area to get the cut tape for sealing operation.
E. Reach out to the sensing area to get the cut tape for sealing operation.
(2) Method 2
A.Turn on the task "On/Off" in the "Program Setting" interface.
B.Switch to Automatic Mode.
C.Press "Start".
D.Reach out to the sensing area to get the cut tape for sealing operation.
In order to achieve the best results, in the process of using the E-404 series
water activated tape dispenser, users need to perform necessary and simple
maintenance. As a supplier of this equipment, we recommend the
following daily maintenance work:
1. Check the water level of the water tank frequently to avoid the poor
effect of the tape wet due to lack of water in the water tank.
2. Regularly clean the water brushes, water tank and water storage tank
with soapy water to avoid the accumulation of adhesive and affect the wet
water effect of the tape.
3. Regularly use lubricating oil to lubricate the rotating parts of the
equipment, such as the bearings and transmission belts, to avoid inflexible
parts that cause running jams or blockages.
4. When the tape is jammed, carefully check and clean the channel to
avoid another paper jam.
www
.kingnodetech.com
Part VI Daily Maintenance
Part VII Common Troubleshooting
During use, some minor faults may occur due to improper installation or
operation. In order not to affect your work, we recommend that you first
check and resolve the faults according to the following methods.
1
2
3
4
5
No. Failure Description
Possible Reasons
Solution
(1) Turn on the power switch of the
equipment.
(2) Make sure the equipment is plugged in.
(3) Turn on the electric outlets or insert the
plug into a power socket.
(1) The device switch is not
turned on.
(2) The equipment plug is not
properly inserted.
(3) The electric outlets are
not working.
External power is
applied, but the
device does not start
normally.
(1) Turn on the power switch of the
equipment.
(2) Move the device to a place with
external power supply for charging.
(1) The device switch is not
turned on.
(2) The battery is low or
exhausted.
No access to an
external power
source, the device
can not be started
properly.
(1) Enter the task editing interface, click
the task status button, and switch "OFF"
to "ON".
(2) Reach out your hand within the
sensing area of the infrared sensor of the
device.
(1) The work order is not opened
and is in the "OFF" state.
(2) The position where the
operator extends the hand is not
within the sensing area of the
infrared sensor of the equipment.
The device can be
turned on normally,
but the device did
not execute the
cutting command to
cut the tape when it
reached out to take
the tape.
(1) Re-install the tape roll as required,
especially check whether the pressure plate
is placed correctly.
(2) Check and thoroughly clean the
channel or water brushes, and perform
regular maintenance as required.
(3) Purchase and use qualified tape.
(1) Improper installation method
of tape roll.
(2) Adhesive residues
accumulate on the channel or
water brushes.
(3) The tape selected by the user
with poor quality.
The tape is often
wrinkled, jammed or
jammed during use.
(1) Thoroughly clean the tape channel,
water brushes or outlet of water tank, and
perform regular maintenance as required.
(2) Add an appropriate amount of water to
in water tank.
(3) Purchase and use qualified water
brushes, and place the brushes as required.
(4) Purchase and use qualified tape; If use
reinforced water activated tape, users need
to install weights on pressure plate.
(5) Press the surface of the tape evenly
and make it evenly stressed during the
sealing process.
(1) There is adhesive residue on
the channel, water brush or
outlet of the water tank.
(2) Insufficient water in the
water tank or storage tank.
(3) The user has replaced the
unqualified wet water brushes or
placed the wet water brushes
improperly.
(4) Poor quality of the adhesive
tape selected by the user.
(5) Unevenly press the tape
during the sealing process.
The tape is not
evenly wet and
sealed nonstick.
Remark: If the problem is still not resolved through the above troubleshooting, please contact our
professional after-sales service personnel.
11
12