Easibath backrests do not as standard have suckers attached to them. These sit on top of the base 
mattress as standard, and the back of the backrest ‘hooks’ under the lip of the top panel of the 
Easibath tub end. 
 
Knee Rests are provided with suckers for attachment directly to the bath tub base. They must not be 
placed on any other material such as another mattress, the suckers will not secure the support 
properly / safely. 

 
 
 
 

The Bathing Process 

 
Before  using  the  bath  /  the  bather  getting  into  the  bath,  the  water  should  be  turned  on  as  described 
below and allowed to flow into the bath with the pop-up waste(s) open to allow any cold water to flow 
away. This process should be continued until the water temperature is perceived to be constant. This 
operation  will  allow  the  mixed  water  temperature  to  increase  to  the  required  level  (if  the  mixer  valve 
option is specified) and permit the carer and/or user to check that the maximum temperature is safe 
prior  to  the  bather  entering  the  bath.  If  the  water  temperature  does  not  achieve  a  comfortable  level 
there may be a fault and the bath should not be used until the fault is rectified. Turn off the water, and 
allow any residual water in the bath to drain. If the temperature achieved was satisfactory, the bath is 
now ready for filling. Close the pop-up waste by operating the push-pull lever or depress the plug itself 
depending on which type is fitted. 

Summary of Contents for EASIBATH

Page 1: ...Please read these instructions carefully before first using your Kingkraft product and then keep them safely for future reference Please also make sure that each person and any carer who uses the bat...

Page 2: ...he Bath Opening Closing Bath Side Bath Mattress Options Tap Control and Shower Options To fill the bath Optional Shower Unit Cleaning Your Bath Mains Powered Easibath BASIC ELECTRICAL CIRCUITS ON BATH...

Page 3: ...g surface The Easibath is not intended for the dependent Bather to be left unattended in the Bath The standard Easibath is available in a choice of three standard models of 1700 1900 and 2100 There is...

Page 4: ...uire that in general no person should lift a mass of greater than 25kg unaided Use appropriate lifting equipment if this is required to help disabled people to get in and out of the bath Your bath mus...

Page 5: ...nder no circumstances must acid or bleach based cleaners be used To do so invalidates your guarantee We recommend that your Kingkraft Bath should be cleaned with Chemgene which is available from us Se...

Page 6: ...t of the bath if there is a fault power failure when the bath is in its highest position The variable height adjustment if specified allows the bath to be raised to working heights suitable for most c...

Page 7: ...ons are made from PVC Please make sure the user will not have any allergic reactions to this material before use Some supports are attached to the base of the bath by suckers In all cases these sucker...

Page 8: ...eration then there is likely to be a fault and the bath raise lower function should not be used further until an engineer has checked the installation and rectified any fault To lower bath side door T...

Page 9: ...op up waste s open to allow any cold water to flow away This process should be continued until the water temperature is perceived to be constant This operation will allow the mixed water temperature t...

Page 10: ...ower Options Hot and Cold taps Reliance Caremix H3 Thermastatic Mixer tap Rada Autotherm 3 Thermastatic Mixer tap Shower Rada Sense System Bath Fill only Rada Sense System Bath Fill and Shower CAT 3 S...

Page 11: ...Board Valves simply open the tap on the bath to start the flow If the bath has conventional hot and cold taps simply turn them both on as required to get the desired mixed temperature REMEMBER THE TE...

Page 12: ...The handset must not be submerged or subjected to pressurised water cleaning If the bath is a static fixed height version there will be no active lifting system but a mains cable current may still be...

Page 13: ...To recharge the battery simply unclip it and attach it to the wall mounted battery charger well away from the wet area and free from interference A light will illuminate when the battery is charging...

Page 14: ...ged by Kingkraft Engineers or qualified electricians and replaced with the correct specified fuse Do not immerse the power cord in water or run over it trap it with mobile devices Lifting Mechanism Wh...

Page 15: ...ext to the head end of the bath tub To vary the amount of turbulence in the bath turn the control button on the bath either clockwise to increase or anti clockwise to decrease the turbulence To adjust...

Page 16: ...ry use Chemgene Trigene is used in the diluted form for general disinfection of the bath surfaces only As an alternative Chemgene Trigene in its concentrated form it can be used for disinfection of th...

Page 17: ...n a bathroom type location where exposed mains connections and unsealed switches etc are not permitted The unit must not be connected via a plug and socket The power supply to the Easibath if powered...

Page 18: ...lower buttons on the handset membrane switch and you can hear a beeping sound coming from the bath you will have to follow this initialisation sequence to re set the bath Failure of the mains power to...

Page 19: ...fill the bath so the water flow is at maximum and record the temperature of the water flowing into the bath 1 3 Set the bath fill control so that the flow of water into the bath is at a minimum and th...

Page 20: ...or damage 9 Check operation of RCD 10 Check all other wires and electrical enclosures for damage 11 Check pipes etc for leaks 12 Check all knobs and handles securely attached 13 Check all controls eas...

Page 21: ...old water isolation valves 6 Hot water supply pressure 7 Cold water supply pressure 8 Hot water supply temperature 9 Cold water supply temperature 10 Outlet temperature at maximum flow 11 Maximum outl...

Page 22: ...The following are examples of markings found on the Easibath Bath identity label Sample Power Actuator Labels These may vary according to the specification of the bath Bath fill control Shower control...

Page 23: ...ithout notice WEEE Waste Electrical and Electronic Equipment Regulations 2006 The aim of this Directive is to minimise the impact of electrical and electronic equipment on the environment when product...

Reviews: