background image

INSTALLATION INSTRUCTIONS

THANK  YOU...

for selecting an American Standard bath. Your new bath is shipped 
to you after careful inspection. The whirlpool version is completely 
assembled with pump, motor, and system piping. All you need to 
finish the installation are your selected fittings and electrical 
connections for a whirlpool.
To insure maximum performance and pleasure from this product, 
please follow the instructions and cautions. 

752878-100 Rev. E

© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

SAVONA OVAL™ 

WHIRLPOOL/BATHING POOL

2903.XXXW SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before enclosing with wallboard, 
tile, etc., water test the unit and check for leaks.
If a whirlpool, do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect the 
safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and enclosing materials are 
provided by others. 

List of Optional Components (not included):

•  Safe-T-Heater 9075.120*

 
List of Required Components (not included):

•  Drain 1583.470*            •  Bath Filler* 

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools

•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun

Supplies

•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  15 amp GFI
      Outlet
•  Cement, Plaster,
      Grout

1524mm

(60)

ROUGH 
FLOOR

1-1/2 O.D.

TAILPIECE

OUTLINE OF

CUTOUT - USE
TEMPLATE

241 mm

(9-1/2)

1073mm

(42-1/4)

489mm

(19-1/4)

INTEGRAL
FEET
SUPPORT

95mm

(3-3/4)

51mm

(2)

537mm

(21-1/8)

76mm

(3)

C

L OF DRAIN

OUTLET

540mm

(21-1/4 )

1-1/2 N.P.T.M.

THREADS

35mm

(1-3/8)

305mm(12) X 229?mm(9)
CUTOUT IN FLOOR FOR DRAIN

98mm
(3-7/8)

PROVIDE ACCESS

TO PUMP FOR

SERVICING ON ALL

INSTALLATIONS

ON/OFF

SWITCH

PUMP
 (MAY 
 EXTEND 
 BEYOND
 RIM BY 1-1/2")

SEE FTTG.SPECS

FOR DIMENSION

CL OF SUPPLIES

C/L OF
SPOUT

C/L OF

VALVES

C/L OF

SHOWER ARM

1651-1981mm

(65-78)

OPTIONAL

102mm
(4)

 

305mm

(12)

SAFE-T-HEATER
REMOVABLE
BLANK

GENERAL SPECIFICATIONS FOR 2903 WHIRLPOOL

60 x 42-1/4 x 21-1/4 In.(1524 x 1073 x 540mm)

107 Lbs. (49 Kg.)

640 Lbs. (291 Kg.)

64 Gal. (243 L)
53 Gal. (201 L)

45 x 23 In. (1143 x 584mm)
53 x 32 In. (1346 x 813mm)

15 In. (381mm)

35 Lbs./Sq.Ft. (166 Kgs./Sq.m)

27.8
45.4

WHIRLPOOL ELECTRICAL SPECIFICATIONS

1.6 HP, 9.7 AMPS, 120V.

SYSTEM I PUMP

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO  OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

Содержание Savona Oval Whirlpool and Bathing Pool 2903.XXXW

Страница 1: ...d must be ordered separately Framing and enclosing materials are provided by others List of Optional Components not included Safe T Heater 9075 120 List of Required Components not included Drain 1583 470 Bath Filler see your American Standard Distributor List of Required Tools and Supplies Tools Level Tape Measure Pipe Wrench Slip Joint Pliers Screw Driver Standard Woodworking Tools Personal Safet...

Страница 2: ...imensions are proper plumb and square For whirlpools provision must be made in all installations for an access opening for servicing pump and controls The following procedure must be used for all installations stringer or pier height should be as indicated The sump of the bath is supported by integral feet and no additional sump support is required Once the bath is in place the feet should be shim...

Страница 3: ...SK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circuit ...

Страница 4: ...HTUB Your new acrylic bathtub has been molded in the newest plumbing fixture material available today Acrylics are tough durable finishes that are simple and easy to care for The colors have been formulated to match other American Standard fixtures and enhance your choice of bathroom decorations The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with pro...

Отзывы: