KI 7010B UM-11
37
APPENDIX
–
REMOTE CONTROL COMMANDS
Manual mode operation commands:
Description
Read wavelength in manual mode ( read wavelength display )
Bytes
87h / 43h / 5bh / checksum
Note
Sends’ Return wavelength ‘ block.
Description
Select wavelength in manual mode ( + - )
Bytes
88h / wavelength / 5bh / checksum
Note
Use before command: Set wavelength in manual mode
Description
Set wavelength in manual mode ( set )
Bytes
89h / 43h / 5bh / checksum
Note
Use after command: Select wavelength in manual mode
Set attenuation commands:
Description
Read current attenuation ( read attenuation display )
Bytes
8ah / 43h / 5bh / checksum
Note
sends ‘ Return current attenuation ‘ block.
Description
Set attenuation ( + - )
Bytes
8bh / attenuation high byte / attenuation low byte / checksum
Set attenuation in Step mode commands:
Description
Set attenuation in step mode ( + - )
Bytes
93h / attenuation high byte / attenuation low byte / checksum