19
Installation
All installation must be carried out by a competent person or quali
fi
ed electrician. Before connecting
the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate.
Direct Connection
The appliance must be connected directly to the mains using an omnipolar circuit breaker with a
minimum opening of 3mm between the contacts.
The installer must ensure that the correct electrical connection has been made and that it complies
with the wiring diagram.
The cable must not be bent or compressed.
Regularly check the power plug and power cord for damage. If the supply cord is damaged, it must
be replaced by a special cord or assembly available from the manufacturer or its service agent.
WARNING: This is a Class II appliance and MUST NOT be earthed
This appliance is supplied with a 2 core mains cable coloured as follows:
Brown = L or Live
Blue = N or Neutral
N
L
N
L
(Blue)
(Brown)
N
L
OFF
USE A 3AMP FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
EUR
UK
FUSE ON
To avoid the risks that are always present when you use an electrical appliance it is important that
this appliance is installed correctly and that you read the safety instructions carefully to avoid misuse
and hazards. Please keep this instruction booklet for future reference and pass it on to any future
owners. After unpacking the appliance please check that it is not damaged. If in doubt, do not use the
appliance but contact Customer Services - see end of Care & maintenance section for details.
Once the electrical connection point and routing
of the mains cable is established ensure that any
excess cable is secured in such a way to prevent
it falling into the motor housing and damaging
the appliance.
Summary of Contents for CHS50
Page 2: ...1 x 2 0 1 x 1 0 1 x 5 0 4 0 06 x6 07 x6 4 x 32mm 08 x4 3 5 x 10mm 03 x1 NEMLI 1 2 x2 6mm...
Page 13: ...00 13 05 04 PP 07 03 03 x1 07 x2 4 x 32 mm 04 01 01 x1 04...
Page 14: ...14 06 07 07 07 x2 4 x 32mm...
Page 15: ...15 09 08 A S lo para la opci n con conducto VENT PACK 150mm 08 05 05 x1 08 x2 3 5 x 10mm A A...
Page 17: ...17 13 12 08 x2 3 5 x 10mm 08 B A 02 02 x1 B...
Page 23: ...23 c 3 II L N N L N L N L OFF EUR UK FUSE ON...
Page 40: ...Benutzung Utilisation Use Utilizare Uso XOODQ P 40 0 01 15 1 2 3...
Page 41: ...Cuidados y Mantenimiento DN P YH 2QDU P QWUHWLHQ HW PDLQWHQDQFH LQHUH 41 01 10 FUSE OFF 10...
Page 42: ...42 02 CARBFILT4 2x CARBFILT4 3 03 1 65 C 1 2...
Page 43: ...43...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ......