15
Important to note :
- The sensor in the heater detects whether a window is open or closed by
measuring abnormal temperature variations. Detection is carried out sev-
eral minutes after the window is opened or closed.
- Detection may be ineffective if these temperature variations are insuffi
-
cient or untimely. This is the case where:
- The difference between the indoor and outdoor temperature is insuffi
-
cient.
- The heater is too far from the window.
- The temperature gradient in the room does not allow for significant tem
-
perature variations in the heater sensor.
- The ambient temperature is not stabilised at least one hour before the
window is opened.
- The temperature setting or mode were modified manually or by a pro
-
gramme before or during detection.
VERSION NUMBERS
This menu displays the equipment and software version number.
- Press
MENU
to access the menus.
- Press ► to select
MENU2
.
- Press
OK
to access the secondary menus
- Press ► or ◄ to select the last menu before
Out
(exit) ; the equipment
version and software version is displayed alternatively.
- Press
MENU
to exit the menus.
Quick start