King Electrical Floor Heating Cable Installation Manual
19
11.1
Before starting any wiring, verify that the power
supply is turned off.
STEP 11: Install the thermostat
11.3
Connect the floor sensor wires to the thermostat.
These are low voltage wires and should not enter
the line voltage junction box. These low voltage
wires typically run through the wall, as shown and
connect into the face of the thermostat away from
the line voltage wires.
11.2
Connect the power supply wires and the load side
heating wires. Follow the thermostat manufacturer’s
instructions.
Lace around end straps
Thermostat wiring diagram
CAUTION:
Allow mortar compound to completely
cure before energizing cable. This will
ensure that the setting of the mortar mix
will not be compromised by the heat of the
cables. Refer to compound manufacturer’s
instructions for curing times.
Line voltage connection
Low voltage connection
Floor sensor wires
Instsall thermostat faceplate