background image

 

  
 
 
 
 
 

 

 

570FEC-HW-X19 

Bulk 10GE FEC Encode/Decode 

with Support for SMPTE2022–7 Hitless Switching 

 

User Manual 

 
 

 
 
 
 
 
 
 
 
 

© Copyright 2020 
 

EVERTZ MICROSYSTEMS LTD. 

5288 John Lucas Drive 
Burlington, Ontario 
Canada L7L 5Z9 
 
Phone: 

+1 905-335-3700 

Sales: 

[email protected] 

Fax: +1 905-335-3573 

Tech Support:  [email protected]  

Fax: +1 905-335-7571 

Web Page: 

http://www.evertz.com

 

 
Version 1.0, March 2020 
 

The material contained in this manual consists of information that is the property of Evertz Microsystems and is intended solely for the use of 
purchasers of the 570FEC-HW-X19  product.  Evertz Microsystems expressly prohibits the use of this manual for any  purpose other than the 
operation of the 570FEC-HW-X19 product.  Due to on going research and development, features and specifications in this manual are subject to 
change without notice. 
 
All rights reserved.  No part of this publication may be reproduced without the express written permission of Evertz Microsystems Ltd.  Copies of 

this manual can be ordered from your Evertz dealer or from Evertz Microsystems

.

 

 

Summary of Contents for 570FEC-HW-X19

Page 1: ...of information that is the property of Evertz Microsystems and is intended solely for the use of purchasers of the 570FEC HW X19 product Evertz Microsystems expressly prohibits the use of this manual for any purpose other than the operation of the 570FEC HW X19 product Due to on going research and development features and specifications in this manual are subject to change without notice All right...

Page 2: ...This page left intentionally blank ...

Page 3: ...ird grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manuf...

Page 4: ... Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communicati...

Page 5: ... warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation to any errors or omissions unless specifically undertaken in...

Page 6: ...570FEC HW X19 Bulk 10GE FEC Encode Decode Page ii Revision 1 0 This page left intentionally blank ...

Page 7: ...4 Data Port Monitor 9 4 1 5 SFP Monitor 10 4 1 6 ARP Control 10 4 1 7 Temperature Monitor 10 4 1 8 Configuration Management 10 4 1 9 Time Management 10 4 1 10 Card Control 10 4 2 PRODUCT FEATURES 11 4 2 1 License Control 11 4 3 FEC CORRECTION CONTROL 12 4 3 1 Main Input Port Control 12 4 3 2 Backup Input Port Control 13 4 3 3 RTP Sequence Error Monitor 14 4 3 4 FEC Monitor 14 4 3 5 IP Bitrate Moni...

Page 8: ...Part 1 of 3 8 Figure 4 4 WebEASY System Section Part 2 of 3 9 Figure 4 5 WebEASY System Section Part 3 of 3 10 Figure 4 6 WebEASY Product Features Section 11 Figure 4 7 WebEASY FEC Correction Control Section Part 1 of 3 12 Figure 4 8 WebEASY FEC Correction Control Section Part 2 of 3 13 Figure 4 9 WebEASY FEC Correction Control Section Part 3 of 3 15 Figure 4 10 WebEASY FEC Insertion Control Secti...

Page 9: ... multi path multi flow packet merge accepting packets from two diverse SFP paths The multi path multi flow based solution allows for bit error resilience and for 100 QoS The 570FEC HW X19 can be managed via integrated HTTP web interface as well as VistaLINK PRO and MAGNUM Unified Control Features Benefits 3 modes of operation Up to 32x bi directional processing paths that can insert FEC and apply ...

Page 10: ...570FEC HW X19 Bulk 10GE FEC Encode Decode Page 2 Revision 1 0 Figure 1 1 570FEC HW X19 Block Diagram ...

Page 11: ...anion rear plate and occupy two slots in 570FR Refer to Figure 2 1 for 570 FEC HW X19 Front plate layout Figure 2 1 570FEC HW X19 Front Plate The front plate of 570FEC HW X19 has 4 available SFP slots These SFP slots can be populated with SFP10G TR13 A This will allow 10G interface to the 570FEC HW X19 Encoder and Decoder ...

Page 12: ... following is required 1 570 Series Frame 2 570 Frame Controller 3 WebEASY using the 570FC frame controller with 570FEC HW X19 installed in frame Before handling the card it is important to minimize the potential effects of static electricity It is therefore recommended that an ESD strap be worn Locate on the chassis 2 adjacent vacant slots Unpack the 570FEC HW X19 and separate the rear panel from...

Page 13: ...ts with FEC insertion FEC insertion Mode 96x IP outputs with FEC insertion FEC Correction Mode 192x IP inputs to allow for 96 processing paths of FEC correction SFP Ports used SFP 1 4 3 2 SFP MODULES 4xSFP modules RTP headers can be enabled or disabled for FEC correct paths 3 3 FEC INSERTION PARAMETERS FEC encoding Pro MPEG forum code of practice 3 release 2 cop3 with L D following the below range...

Page 14: ...570FEC HW X19 Bulk 10GE FEC Encode Decode Page 6 Revision 1 0 This page left intentionally blank ...

Page 15: ... network addresses it can be completely configured using the web interface For doing this simply type the IP address of the control port of the 570FEC HW X19 module in the web browser Note Computer must be on the same Subnet in order to have communication with the module Figure 4 1 WebEASY Login Menu Login and password is root and evertz respectively On the web interface there are several differen...

Page 16: ... the user to set the Netmask for control port Gateway This parameter allows the user to set the Gateway for control port Please note the control port is only used when the 570FEC HW X19 is used in the S570FR 4 1 3 Data Port Configuration For SFPP 1 to 4 IP Address This parameter allows the user to set the IP address for data port Netmask This parameter allows the user to set the Netmask for data p...

Page 17: ... kbps Rx Frame Count This parameter displays the received Rx frames on this Ethernet port Rx CRC Error Frame Count This parameter displays the received Rx frames with CRC errors on this Ethernet port Rx Undersized Frame Count This parameter displays the received Rx undersized frames on this Ethernet port Rx Oversized Frame Count This parameter displays the received Rx oversized frames on this Ethe...

Page 18: ...e IP address used for Gratuitous ARP Figure 4 5 WebEASY System Section Part 3 of 3 4 1 7 Temperature Monitor Temperature This field monitors the current temperature of module 4 1 8 Configuration Management Export Configure File This control allows the user to save config data to JSON file and download the JSON file to local host Import Configure File This control allows the user to load config JSO...

Page 19: ...Revision 1 0 Page 11 4 2 PRODUCT FEATURES Figure 4 6 WebEASY Product Features Section 4 2 1 License Control Product Serial Number This parameter displays the card s serial number Product Mac Address This parameter displays the card MAC address ...

Page 20: ...h channel will obtain their main stream source from Main Input IP Address This field allows the user to set the input IP address multicast address Main Input IP Port Number This field allows the user to select the input UDP port number Main Input IGMPV3 Mode This parameter allows the user to select the IGMP V3 mode to use Main IGMPV3 SSM Src1 6 IP Address This field allows the user to set the IP a...

Page 21: ... field allows the user to set the backup input IP address multicast address Backup input IP Port Number This field allows the user to select the input UDP port number Backup input IGMPV3 Mode This parameter allows the user to include exclude the backup IGMP V3 to use Backup IGMPV3 SSM Src1 6 IP Address This field allows the user to set the IP addresses which will be used while forming the source f...

Page 22: ...or Count Count increments when a packet is dropped on the Main FEC Stream 1 Main FEC Stream 2 Error Count Count increments when a packet is dropped on the Main FEC Stream 2 Backup Media Stream Error Count Count increments when a packet is dropped on the Backup Stream Backup FEC Stream 1 Error Count Count increments when a packet is dropped on the Backup FEC Stream 1 Backup FEC Stream 2 Error Count...

Page 23: ...ate This field reflects the backup input FEC stream 2 bitrate Output Stream Bit Rate This field displays data stream bitrate 4 3 6 Output IP Control For FEC Rx1 to FEC Rx32 IP Output Enable This field allows the user to enable disable the output IP Output Source IP Address This field allows the user to set the source IP address IP Output Source UDP Port This field allows the user to set the source...

Page 24: ...Revision 1 0 4 3 7 Settings Log Control Statistics This button allows the user to choose whether or not to log statistics for this channel The logs will be available via syslog 4 4 FEC INSERTION CONTROL Figure 4 10 WebEASY FEC Insertion Control Section ...

Page 25: ...ld displays the Input RTP sequence errors Input Bit Rate Detected This field displays the detected input Bitrate Clear input Statistics This control allows the user to reset received IP statistics 4 4 3 FEC Control For FEC Tx1 to FEC Tx32 FEC Mode This dropdown allows the user to set the FEC mode which can be toggled for each stream FEC Column This dropdown allows the user to set the FEC column FE...

Page 26: ... System Monitoring Control Temperature Warning Threshold This field allows the user to set the temperature threshold for the overheat temperature 4 5 2 System Notify System Traps This control allows the user to turn traps On or Off System Faults This parameter allows the user to check whether a fault is currently present or not ...

Page 27: ... field allows the user to set the error threshold before an alarm is sent Time Frame This parameter allows the user to set the time frame after which a condition is triggered 4 6 2 FEC Correction Notify For FEC Rx1 to FEC Rx32 System Traps This dropdown allows the user to turn the traps On or Off System Faults This display will reflect green if there is no fault and will reflect red for a fault in...

Page 28: ...his control allows the user to set a threshold for RTP Sequence Error Time Frame This control allows the user to set the time frame after which the condition is triggered 4 7 2 FEC Insertion Notify For FEC Tx1 to FEC Tx32 System Traps This dropdown allows the user to turn the traps On or Off System Faults This display will reflect green if there is no fault and will reflect red for a fault indicat...

Page 29: ...C Insertion Notify Section 4 8 1 SNMPv1 Trap Destinations Add Trap Destination This field allows the user to set an IP address for a new trap destination IP Address This field will display IP address for any currently set trap destinations Clear This button will clear a currently set trap destination ...

Page 30: ...570FEC HW X19 Bulk 10GE FEC Encode Decode Page 22 Revision 1 0 This page left intentionally blank ...

Page 31: ...mware version and upload the latest firmware Figure 5 1 Figure 5 1 WebEASY Upgrade Button on Top Menu Bar Selecting the Upgrade tab will take the user to Figure 5 2 where the current firmware version is shown Should the firmware version be outdated the user needs to download the firmware image file Figure 5 2 WebEASY Firmware Upgrade Menu Click choose file and browse to locate image file Figure 5 ...

Page 32: ...570FEC HW X19 Bulk 10GE FEC Encode Decode Page 24 Revision 1 0 Figure 5 3 WebEASY Firmware Upgrade Menu ...

Reviews: