8
TOOLS NEEDED
Screwdriver
Pipe Wrench
MATERIALS NEEDED
Pipe Thread
Tape
or Sealant
Two Hose Adapters
1½” X 1½” X 1¼”
Two Sections of 1½”
or 1¼” Flex Hose
Two
Hose
Clamps
RECOMMENDED
4-8 psi Back Pressure
To avoid over or under chlorination,
replace eyeball fi ttings in the
return jets to a smaller or larger
size to adjust back pressure. For
best results use King Technology’s
pressure gauge, order part number
01-22-4000.
Apply pipe thread tape or sealant
to the threaded end of both hose
adapters.
1.
Base Flex-Hose Installation
Screw adapters into each end of FROG
Leap Infuzer. Hand tighten. Finish tightening
by turning 1 to 2 revolutions with a pipe
wrench.
DO NOT OVER TIGHTEN.
2.
Attach the fi lter section of fl ex hose to one hose adapter and
the return section of fl ex hose to the other hose adapter with
clamps and tighten with screwdriver. Bi-fl ow valve design
allows water fl ow in either direction.
3.
To prevent damage to heaters
or fi lters, see your dealer about
installing a
corrosion resistant
check valve
which will reduce the
back fl ow of chlorine gas when the
Infuzer is turned off.
4.
For better stability, FROG Leap Infuzer may be mounted
on a treated wood base using
Phillips pan head
screws,
one in front and two in back. If you have
questions about stability, please contact your dealer or
King Technology.
5.
4/0//,
05-0
&),4%2
HOSE
CLAMP
HOSE
ADAPTER
HOSE
CLAMP
HOSE
ADAPTER
TO POOL
1 1/2" OR 1 1/4"
FLEX HOSE
1 1/2"
X
1 1/2"
X
1 1/4"
HOSE ADAPTER
HOSE
CLAMP
FILTER &
PUMP
CHECK
VALVE
The FROG Leap Infuzer should always be installed
between the fi lter and pool (or between heater and
pool if applicable).
Never install
FROG Leap
before
the heater or damage to the heater could occur.