GSM/GPRS/3G/4G/NB-IoT
Sensor To Cloud IoT Series
Page 36 of 37
King Pigeon Hi-Tech. Co., Ltd
Ver 1.1
Inquiry network parameter
Pa AP
Delete network parameter
Pa APDEL
Set
server
parameters
IP1
Pa IP + ‘IP address or domain
name’ + * + ‘port number’
The server 1 is main server,
server 2 is alternate server.
IP2
Pa IPB +‘IP address or domain
name’ + * + ‘port number’
Inquiry
server
parameters
IP1
Pa IP
IP2
Pa IPB
Delete
server
parameters
IP1
Pa IPDEL
IP2
Pa IPBDEL
Enable network - Online
Pa GPRSonline
Enable transmission protocol
Disable network - Offline
Pa GPRSOFF
Disable transmission protocol
Set Login Message
Pa RTP + ‘Login Message’
Inquiry Login Message
Pa RTE
Set Heartbeat Message
Pa HET + ‘Heartbeat Message’
Only for Modbus protocol
Inquiry Heartbeat Message
Pa HEE
Set the Heartbeat Interval
Pa HT + ‘interval time’
The Interval time is 0~9999,
unit second, default 60.
Inquiry
the
Heartbeat
Interval
Pa HTE
DO output close
Pa DOC
Only for DO output;
The close time is 0-65535, unit
second, default 0, indicating
that the pulse output is always
closed.
DO output open
Pa DOO
Query the current state
Pa DOE
Pulse output close time
Pa DOT + ‘close time’
Query pulse close time
Pa DOT
Control pulse output
Pa DOP
Set threshold high and low
Pa AINR + ‘serial number’ + L
+ ‘threshold low’ + H + ‘threshold high’
+ #
Only for AIN, DS18B20,
AM2301 input;
The serial number is 1 or 2 (1
represents AIN or temperature,
2 represents humidity);
The
threshold
low
and
threshold high of AIN and
temperature should be set at 10
times the actual value.
Inquiry threshold high and
low
Pa AINR
Set the range of AIN
Pa AINM + L + ‘minimum’ + H
+ ‘maximum’ + #
Only for AIN input;
The minimum and maximum
should be set at 10 times the
actual value.
Inquiry the range of AIN
Pa AINM
Calibrate the accuracy of
AIN
Pa VOL=‘calibration value’
Only for AIN input;
The
calibration
value
is
generally 3200~3400;
The
factory
accuracy
is
calibrated and please do not set
Inquiry the calibration value
of AIN
Pa VOL