background image

 

 

 

 Page 1 of 16       King Pigeon Hi-Tech. Co., Ltd.   Page 1 of 16  Ver 1.0    File No.:RTU501610 

A Professional GSM Alarm System designer and manufacturer! 
GSM Transformer Alarm System &GSM House Alarm System& 
GSM Telemetry Units & GSM GPRS Logging System 
Http://www.GSMalarmsystem.com  [email protected]

 

Automatically

 

monitoring

 

Air

Conditioner

 

by

 

SMS

 

Text!

 

Remotely

 

Control

 

Air

Conditioner

 

by

 

SMS

 

Text!

 

Temperature

 

Monitoring

 

by

 

SMS

 

Text!

 

 

GSM SMS IR CONTROLLER 

RTU5016 

User Manual 

Ver 1.0    Date Issued: 2012-03-05 

All rights reserved by King Pigeon Hi-Tech. Co., Ltd. 

Website: 

Http://www.GSMalarmsystem.com

     

Summary of Contents for GSM SMS IR CONTROLLER RTU5016

Page 1: ...GSM Telemetry Units GSM GPRS Logging System Http www GSMalarmsystem com Sales KingPigeon com cn Automatically monitoring Air Conditioner by SMS Text Remotely Control Air Conditioner by SMS Text Tempe...

Page 2: ...ty 15 This handbook has been designed as a guide to the installation and operation of RTU5016 GSM SMS IR Controller Statements contained in the handbook are general guidelines only and in no way are d...

Page 3: ...authorized temperature monitoring remote control Air Conditioner Actually the GSM SMS IR Controller RTU5016 can be used in places which require to use Infrared Remote to control e g Air Conditioner Te...

Page 4: ...o owners low than 10 should automatically switch on the heater Air Conditioner to heat up the temperature and warning owners by SMS 6 Switch ON OFF equipments e g motor Air Conditioner and other elect...

Page 5: ...been reset to default settings Learning This button for learning IR Air Conditioner s Infrared Remote Transmitter OFF T1 6 T1 Position Led when learning IR signal to T1 will flick after learned succe...

Page 6: ...de 25 10K 1 precision included in standard package input to convert the temperature to digital value 2 Lower or Higher warning temperature threshold value can be configured 3 Can inquire the current t...

Page 7: ...tc Don t add spaces or any other character When input punctuation symbol must be under ENGLISH or DIGITAL input method Not support other input method 5 When external AC goes off and goes on will send...

Page 8: ...s 1234 then you can send 1234 TEL004413500001111 01 to the RTU5016 unit After the RTU5016 received the 0044 is country code will return For example In UK the country code is 0044 or 44 The user cell p...

Page 9: ...thorized Number 6 5 Inquiry the assigned IR value information After the RTU5016 received will return Tips The GSM SMS IR Controller can be saved 5 different temperature value The T1 position is for as...

Page 10: ...itch On the Air Conditioner automatically when low temperature alarm occurrence Reply Tips in Tx the x 1 6 Stands for T1 T6 This command means when low temperature alarm will switch on the Air Conditi...

Page 11: ...temperature alarm occurrence Reply 7 Switch On the Air Conditioner automatically when High temperature alarm occurrence Reply Tips The Tx is the same means of abovementioned x 1 6 Please pay attentio...

Page 12: ...immediately 6 9 Switch OFF the Relay Output Reply 6 10 Switch ON Air Conditioner and setup its temperature The Tx stands for T2 T6 T1 is special for switch off the air conditioner please see 6 11 For...

Page 13: ...l saved IR Transmitter signals at T1 T6 And enter into learning mode The T1 Led will flick and the Status Led will be red and green color Step2 Press the Learning Button till the Status Led change to...

Page 14: ...d the signal will save it at position T2 2 When you want to learn the Switch OFF button function to the GSM SMS IR Controller then press the Learning Button when the T1 Led flicks and status led is re...

Page 15: ...mission range and there re with a power source as well as enough GSM signal coverage The distance from the GSM SMS IR Controller must be less than 3meters to the Air Conditioner 8 Technical specificat...

Page 16: ...ler off and switch it on after one minute Test this system after another minute or check the settings are correct and the GSM Signals are strong enough 3 If the GSM SMS IR Controller can run and senso...

Reviews: