background image

 

 

 

 Page 16 of 17       King Pigeon Hi-Tech. Co., Ltd.   Page 16 of 17  Ver 1.1    File No.:KPA1010 

A Professional GSM Alarm System designer and manufacturer! 
GSM SMS Controller System &GSM House Alarm System& 
GSM Elderly Guarder & GPRS Telemetry Data Logger. 

Http://www.GSMalarmsystem.com 

 

         

 

9.2 Install the Control Panel 

The Control Panel should be installed in the position that person can easily touch it, and there’re with a 
power source as well as enough GSM signal coverage. But make sure it is far away the electricity 
equipments, and 10meters away from the wireless strobe siren to avoid the interference. 

9.3 Install the Wireless Accessories 

1)  The Wireless PIR Motion detectors are used for monitoring the person movement. We recommend 

assigning them to Watchdog Zone. So please install them in the positions where the person must pass 
through, like the door of the bedroom, dining room, cooking room, and washing room, etc. The effective 
detection area is about 8-12meters front of the wireless PIR Motion Detector, more about it please read 
the PIR Motion Detector user manual. 

2)  The Wireless Gas Leakage detector is for monitoring the gas leakage, LPG leakage. We recommend 

assigning it to 24 Hours Zone. So please install it nearby the gas valve or gas bottle. More about it please 
read its user manual. 

3)  The Wireless Smoke Detector is for monitoring the smoke, fire alarm. We recommend assigning it to 24 

Hours Zone. So please install it in the place where easily to cause fire case. More about it please read its 
user manual. 

4)  The wireless water leakage detector is for monitoring the water leakage and flood. We recommend 

assigning it to 24 Hours Zone. More about it please read its user manual. 

5)  The Wireless Panic Button or worn waterproof is for emergency help. We recommend assigning them to 

the Panic Button Zones. 

6)  The Wireless Strobe Siren is for warning when any alarm occurrence. We recommend installing it about 

10meters away from the control panel. And nearby the windows, so that when the strobe siren alarming, 
the outside people can see it easily. The Control panel can accept more than one wireless strobe siren. 

10. Technical specifications 

Parameter Item 

Reference Scope 

DC Power supply 

Standard adapter: DC9V/1A 

GSM Frequency 

Quad-band(850/900/1800/1900Mhz) 

SIM Card 

Supporting 3V SIM Card 

GSM Antenna

50 

 SMA Antenna interface, internal. 

Wireless Frequency 

433.92Mhz 

Worn Panic Button Transmission Dist. 

60meters in open air. 

Wireless Detectors Transmission Dist. 

100meters in open air 

Acceptable Max. Worn Panic Button 

3Pcs(If not use 24-Hour zones then is 6Pcs) 

Acceptable Max. Wireless Detectors 

7Pcs(4 for watchdog zones, 3 for 24-Hour zones, if not use Worn Panic 
Button and Wireless Panic Button then is 6Pcs for 24-Hour Zones ) 

Acceptable Max. Wireless Strobe Siren 

Unlimited (Optional Function) 

Max. Distance of the Wireless Siren Transmitter

100meters in open air(Optional Function) 

Backup Battery 

3.7V 900mAh Rechargeable Lithium Battery

 

Temperature range 

-20-+60 °C 

Humidity range

Relative humidity 90% (condensation free) 

Exterior dimension 

80mm*90mm*20mm 

Net Weight

300 g 

Summary of Contents for GSM Elderly Guarder

Page 1: ...ystem designer and manufacturer GSM SMS Controller System GSM House Alarm System GSM Elderly Guarder GPRS Telemetry Data Logger Http www GSMalarmsystem com GSM Elderly Guarder User Manual Ver 1 1 Date Issued 2011 06 20 All rights reserved by King Pigeon Hi Tech Co Ltd Website Http www GSMalarmsystem com ...

Page 2: ...ications 16 11 Quality Warranty 17 12 Trouble Shooting Guide 17 This handbook has been designed as a guide to the installation and operation of A10 GSM Elderly Guarder Statements contained in the handbook are general guidelines only and in no way are designed to supersede the instructions contained with other products King Pigeon Hi Tech Co Ltd its employees and distributors accept no liability fo...

Page 3: ...Elderly Guarder with user friendly design idea all operations and settings can be programmed by PC Configurator or remotely by SMS commands The GSM Elderly Guarder will make you live safe live free and enjoy life 2 Safety Directions Safe Startup Do not use GSM Elderly Guarder when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might inter...

Page 4: ...y Number directly No 2 The 2nd Familiarity Number Button push it to call the 2nd Familiarity Number directly No 3 The 3rd Familiarity Number Button push it to call the 3rd Familiarity Number directly SOS The SOS Button push it to send out SMS to 3 SMS Alert Numbers and autodial the 5 Alarm Dial Numbers directly Stop The Stop Button push it to stop the current operations or push it to answer the in...

Page 5: ...der GPRS Telemetry Data Logger Http www GSMalarmsystem com GSM Antenna This place with very thin plastic if need use external GSM Antenna then please poke and make a hole then fix the GSM Antenna connector ON OFF The Switch to power on off of the unit USB Port For downloading the settings from the PC configurator DC12V External Power input for the control panel the range is DC 9 12V 1 2A 5 Feature...

Page 6: ...so the familiarity can call in to create the two way voice communication automatically 7 Large Capacity Rechargeable Backup Battery The 900mAh large capacity rechargeable backup battery is useful to ensure it can work about 12hours after AC power is failure Also when the AC power goes off it will send a SMS to the Cell phone number 8 Self checking Function The Self checking function is very useful...

Page 7: ...e in the preset time Usually use the wireless PIR motion detector for it E g if the mother hasn t gone out the bedroom in 6 00 12 00AM then maybe she is ill Should send SMS to alert 24 Hour Zone In any time if the detectors with this type triggered will alarm e g smoke detector triggered gas leakage detector triggered flood detector triggered it should send SMS to alert Panic Button In any time if...

Page 8: ...an not setup it successfully Step1 Please Contact the unit to the PC and then install the USB Driver to the computer from the CD firstly When successful it can be found out at the device manager of the XP or Windows 7 please see the below photo And remember the COM port Also the driver can be downloaded from Silicon Laboratories Inc the model is CP210x If the Com port is not Com1 Com5 then please ...

Page 9: ...es on the GSM Elderly Guarder after 2Seconds it will alert Download Success when the Setup successful Step 7 Power off the unit then remove the USB cable Then power on the Unit to finish the setup If it hasn t prompted the setup successful then means the setup is failure please check the Com port and USB connection then try to repeat the Step1 Step6 again If you want to use the Read Settings Load ...

Page 10: ...le this function The formart is 24 Hour type should be two digital Eg 01 05 Com Port Select the Com port to communicate between GSM Elderly Guarder and Computer Save Settings Save the settings from computer to GSM Elderly Guarder Read Settings Read the settings from GSM Elderly Guarder to computer Save Profile Save the settings as file to computer Load Profile Load the settings from the Saved file...

Page 11: ...d is 1234 and the Familiarity No 1 is 13500001111 so the SMS Content of this command to setup the Familiarity No 1 is 6 2 2 Setup the SMS Contents by SMS Commands SMS Command Format Password M Serial Number SMS Content The Serial Number of the zones please see the table Notice The SMS Content accept Max 63 characters please pay attention to it Serial Number Zone Name 1 1st Watchdog Zone 2 2nd Watc...

Page 12: ...ther switches must be in OFF position Zones Attribute Numbers on Switch Positions Watchdog Switch1 4 24 Hour Zone Switch5 7 Panic Button Switch8 10 7 1 Add the Wireless PIR Motion Detector to Watchdog zones of the Control Panel When the Control Panel in the learning mode then switch the Switch1 from OFF to ON and trigger the PIR Motion Detector by pass though it the Control Panel will learn the co...

Page 13: ...detectors the Control Panel will learn the code from the wireless Detector automatically When alert by long Di sounds means the wireless Detector was learned to the Switch5 Position please switch the switch back to OFF If alert by Di Di two sounds then means the operation failure please switch it back to OFF then retry again Switch the Switch6 Switch7 from OFF to ON one by one to learn the 2nd 3rd...

Page 14: ...ode from the Panic Button automatically When alert by long Di sounds means the Panic Button was learned to the A7 Position please switch the switch back to OFF If alert by Di Di two sounds then means the operation failure please switch it back to OFF then retry again Switch the switch9 Switch10 from OFF to ON one by one to learn the 2nd 3rd Panic Buttons to the Control Panel Wireless Waterproof Pa...

Page 15: ... S1 nearby the SIMCard Socket Switch on the Control Panel about 3Seconds later the control panel will make Di Di Di 3 sounds then loose the reset button means the reset operation successful After this operation all the added wireless detectors and wireless panic buttons will be removed from the control panel and all of the settings will be reset to the factory default 9 Installation Before install...

Page 16: ...ere easily to cause fire case More about it please read its user manual 4 The wireless water leakage detector is for monitoring the water leakage and flood We recommend assigning it to 24 Hours Zone More about it please read its user manual 5 The Wireless Panic Button or worn waterproof is for emergency help We recommend assigning them to the Panic Button Zones 6 The Wireless Strobe Siren is for w...

Page 17: ...rt 1 Backup battery with low voltage 1 Please help to contact the AC Power False Alarm 1 PIR Motion sensor installation incorrect 1 Please see the PIR Motion sensor installation user manual carefully Alarm without SMS Dial No action after send SMS 1 GSM Operator communication protocol 2 Haven t setup SMS Alert Auto dial Numbers 3 Caps Lock letters in the SMS 1 Please setup the SMS Alert Numbers 2 ...

Reviews: