background image

 

 

 

    Page 3 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

1. Brief Introduction 

The GSM 3G M2M RTU inbuilts 

ARM® Cortex™ 32 Bit RISC Core, 168 MHz inside, RTOS system. It is a multi 

I/O  port  remote  terminal  unit,  through  the  RS232/485  port  can  extend  up  to  64  additional  I/O  or  connect 
intelligent meters or PLC. It is special for BTS monitoring, remote data acquisition, telemetry, BTS monitoring, 
access  control,  ATM,  generator  monitoring,  Pump  station  monitoring,  weather  satiation  monitoring  and  other 
applications. It supports voice communication, SMS, GPRS, 3G and RJ45 LAN IP communications.   
 
The GSM 3G M2M RTU can be used as remote access control. The authorized users can open the gate or turn 
on the machine with a free charge call at specified time. 
 
The GSM 3G M2M RTU supports Modbus RTU, Modbus TCP, TCP/UDP protocol, transparent data 
transmission over GPRS/3G, RS232, RS485, RJ45, performs as Modbus Master or Modbus Slave. It can 
integrate into present SCADA or DCS or HMI directly. 
 
The GSM 3G M2M RTU can be used as Modbus RTU SMS Alert Alarm, when the data acquisition from 
RS232/485 exceeds threshold value, it also can send pre-definition SMS to users. 
 

The GSM 3G M2M RTU can be used as: 

 

A Switch with SMS Remote Control

. SMS texts for switching particular terminals on/off are 

configurable.   

 

A Modbus RTU SMS Alarm

. It can be used as Modbus RTU SMS Alarm, when the data/value 

acquisition from RS232/485 exceed the threshold, it can send SMS to alert the users immediately. 

 

A Timer-Switch which can be activated automatically

. It can be used as preset time when the GSM 

3G M2M RTU 

need work and when it needn‘t work.   

 

An Access Control unit.

 Up to 10 tel. numbers can be authorized for dial to access control and open 

the electricity door directly with free charge. 

 

An automation system.

 Each input can link to output actions, this is very useful when the temperature 

upto appointed value, need switch on the air-conditioning immediately, or when water overflow and need 

switch on the dryer, or when somebody broken into the door or windows need to start the CCTV and 

Siren.   

 

A SMS reporter.

 The GSM 3G M2M RTU can setup daily automatically report its current status to users. 

 

A SMS Alarm Controller.

 The IO activations or deactivations can be reported by SMS and optionally 

confirmed by phone calls. Each input can have its own message texts and the message can be 

programmed by users.   

 

A Pulse Counter. 

The digital inputs can be used as the pulse counter, the user can setup both of interval 

value activated alarm and total value activated alarm. 

 

A Data Logger. 

The unit can save the all of the acquisition data in internal memory storage and upload 

to internet by GPRS /3G/RJ45/RS232/RS485 network according to schedue, no distance limitation.   

 

A Wireless Data Acquisition to SCADA or HMI or Monitoring Center. 

The unit can acquisition the 

varity data(E.g.: Pressure, Level, Current, Voltage, digital input status, pulse counter, digital relay output 

status, temperature value, humidity value and other) and upload to the SCADA(Real time dynamic data) 

or HMI or Monitoring Center by SMS/GPRS/3G/RJ45/RS232/RS485, no distance limitation. 

 

A Wireless Intelligent Meter Reader.

 The GSM 3G M2M RTU can be used to read remotely intelligent 

meter data to SCADA or monitoring center by RS232 port or RS485 Port. 

Summary of Contents for GSM 3G M2M RTU

Page 1: ...GSM 3G IOT M2M Solution User Manual Ver 1 0 S27x Date Issued 2015 04 20 All rights reserved by King Pigeon Comm Co Limited www GSM M2M com GSM 3G M2M RTU ...

Page 2: ... USB cable 1x User Manual 1x Backup battery inside 1x TF card inside Terminals for Connection 4 The standard package not includes SIMCard Temperature Humidity sensor TH100 Warning Tips This User manual is for S275 for other models please refer to this user manual and note abovementioned differences This handbook has been designed as a guide to the installation and operation of RTU S27x Statements ...

Page 3: ...used as preset time when the GSM 3G M2M RTU need work and when it needn t work An Access Control unit Up to 10 tel numbers can be authorized for dial to access control and open the electricity door directly with free charge An automation system Each input can link to output actions this is very useful when the temperature upto appointed value need switch on the air conditioning immediately or when...

Page 4: ...visioning center the own can remote monitoring and control the remotely terminals by GPRS 3G RJ45 LAN Network This is very useful to Fuel tank monitoring Oxygen in hospital Flood level street light control wellhead control BTS environment monitoring power transmission system monitoring and other applications 1 1 Typically Applications Typically BTS Solution Diagram ...

Page 5: ...mA 4 20mA 5 4 Relay outputs 5A 30VDC 5A 250VAC 6 8 digital inputs dry contact or level input One of the input can be used as counter 7 1 temperature probe input 1 humidity transducer input 8 I O ports with opto isolated RS232 485 with 15KV ESD protection 9 2 IP data centers supports Modbus TCP TCP IP protocol over GPRS 3G RJ45 LAN network 10 RS232 RS485 can performs Modbus RTU Master Modbus RTU Sl...

Page 6: ...esolution 0 5V or 0 20mA or 4 20mA Temp Hum Inputs TH100 Range Temperature 40 C to 80 C Humidity 0 100 RH Relay Outputs 4 Rated 5A 30VDC 5A 250VAC Power Outputs 2 Port for external device Memory Capacity Internal Memory inside can save the data for 1000events Backup Battery 3 7V 1200mAH Temperature range 10 70 C Humidity range Relative humidity 95 condensation free Exterior dimension 168mm 113mm 3...

Page 7: ...r normally is off T H Temperature Humidity sensor TH100 inputs Power Connector Definition DC IN External Power Connector Connect to 1 5A 9 36V DC power through AC DC Adaptor positive electrode DC IN External Power Connector negative electrode DC Out See above mentioned photo Digital Relay Output Connector Definition DO Digital Relay Output 4 positive electrode NO GND Digital Relay Output 4 negativ...

Page 8: ...e Contact the unit to the PC by USB Cable and then install the USB Driver to the computer from the CD firstly When successful it can be found out at the device manager of the XP or Windows 7 please see the below photo Also the driver for different OS can be downloaded from Silicon Laboratories Inc http www silabs com the model is CP210x Step2 Connection Please insert the SIMCard and install the GS...

Page 9: ...uration page as below Step4 Configuration Parameters The GSM 3G M2M RTU configurator is a user friendly design software all of the parameters and ranges are describe clearly please read the notices carefully to save you configuration time Also for daily operate we are strongly recommend the user use the App 5 SMS commands APP The user can send SMS commands to setup or operate the GSM 3G M2M RTU al...

Page 10: ...er Goes OFF External DC Power Goes ON External DC Power Goes ON 3 Modify Password 4digits default is 1234 SMS Command Return SMS Content Old Password P New Password This is the New Password please remember it carefully 4 Arm Disarm SMS Command SMS Command Return SMS Content Arm password AA Armed Disarm password BB Disarmed 5 Set RTU time format is 2015 05 22 15 20 30W01 the W01 stands for Monday W...

Page 11: ...es number S start time E endtime Always can access control password B series number P Notice Time format is 201505231230 stands for year month date hour minute Tel1 Tel2 Tel3 13570810254 Tel4 Tel5 Inquiry password B Return all authorized user numbers Delete password B series number Return all authorized user numbers 9 Setup Daily Report time SMS Command Return SMS Content Setup password DR series ...

Page 12: ...AINM channel number DEL Inquiry AIN Current Value password AINE channel number nnnnnnnn AINx xxxx Normal Higher Lower Inquiry All AIN Current Value password AINE AIN0 xxxx Normal Higher Lower AIN1 xxxx Normal Higher Lower 12 SMS Control Digital Output SMS Command Return SMS Content Set DO Name password DO channel number T DOx xxxx Inquiry DO Name password DO channel number nnnn Delete DO Name pass...

Page 13: ...ations It is very useful for users to create remotely or local monitoring server It inbuilt standard Modbus RTU Modbus TCP transparent data transmission protocol and definition protocol the user can connect the GSM 3G M2M RTU to the present HMI OPC Server SCADA directly 6 1 Modbus RTU Modbus TCP Protocol The GSM 3G M2M RTU supports standard Modbus RTU and Modbus TCP protocol the user can use the s...

Page 14: ...oner generator meters instruments transducers sensors PLC and so on The user no need to create or change its present server protocol and can use it directly At this condition the GSM 3G M2M RTU performs a SMS Alarm and SMS Controller and DTU and Modbus RTU Slave The topological graphs please see below RTU Existing Server Modbus RTU Server Non Modbus RTU Meters or Devices Transparent Data Transmiss...

Page 15: ...e them directly by USB port if you required upgrade please contact us to modify the firmware according to you requirements and we will provide the upgraded firmware to you to upgrade them 9 Warranty 1 The RTU is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or m...