Page 10 of 15 Ver 1.0 File No.:S27x10
GSM 3G M2M RTU
Automation solution
The SMS commands are below:
1)
Commands error return SMS
Event
Return SMS Content
Any incorrect Command
SMS Format Error, Please check Caps Lock in Command!
2)
External DC Status
Event
Return SMS Content
External DC goes off
External DC Power Goes OFF
External DC Power Goes ON
External DC Power Goes ON
3)
Modify Password, 4digits, default is 1234
SMS Command
Return SMS Content
Old Password
+
P
+
New Password
This is the New Password, please remember it carefully.
4)
Arm/Disarm SMS Command
SMS Command
Return SMS Content
Arm
pAA
Armed
Disarm
pBB
Disarmed
5)
Set RTU time, format is 2015-05-22 15:20:30W01, the W01 stands for Monday, W07 stands for Sunday.
SMS Command
Return SMS Content
pDxxxxxxxTxxxxxWxx
xxxx(Y)XX(M)XX(D)xx(H)X(M)xx(W)