background image

 

 

 

    Page 2 of 15                            Ver 1.0 File No.:S27x10 

GSM 3G M2M RTU     

Automation solution

 

 

Table of contents 

1.

 

Brief  introduction 

-------------------------------------------------------------------------------------------------4 

2.

 

Safety Directions

 ---------------------------------------------------------------------------------------------------6 

3.

 

Physical  Layout

 ----------------------------------------------------------------------------------------------------7 

4.

 

Settings

  ---------------------------------------------------------------------------------------------------------------8 

5.

  SMS commands & APP

-------------------------------------------------------------------------------------------9

 

6.

  Communication  Protocol

--------------------------------------------------------------------------------------13

 

7.

  Registers Assignment Table

----------------------------------------------------------------------------------14

 

8. 

Upgrade  Firmware  ------

----------------------------------------------------------------------------------------15

 

9. 

Warranty

  -----------------------------------------------------------------------------------------------------------15 

 

 

 

 

 

Model GSM/3G  Precision 

DIN  AIN 

DO 

Register 

Record 

Port 

S270 

12bit 

1000 

USB 

S271 

12bit 

1000 

 

S272 

12bit 

TF Card 

USB/RS232/RS485 

S273 

12bit 

64 

TF Card 

S275 

16bit 

64 

TF Card 

USB/RS232/RS485/RJ45 

Notice 

1.

 

For 3G Version, the model should plus C or W, C stands for inbuilt module is CDMA2000. W stands 
for inbuilt module is WCDMA; 

2.

 

All of them support 1 temperature and 1 humidity inputs for environment monitoring. 

3.

 

The standard package:   
1x RTU, 1x GSM Antenna, 1x AC/DC Adaptor,1x Android APP, 1x PC Configuration Software, 
1x USB cable, 1x User Manual, 1x Backup battery inside, 1x TF card inside, Terminals for Connection. 

4.

 

The standard package not includes: SIMCard , TempHumidity sensor TH100 

Warning Tips: 

This User manual is for S275, for other models please refer to this user 

manual and note abovementioned differences. 

This handbook has been designed as a guide to the installation and operation of RTU S27x. 

Statements contained in the handbook are general guidelines only and in no way are designed to supersede the 

instructions contained with other products. 

We recommend that the advice of a registered electrician be sought before any Installation work commences. 

King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for any loss or damage 

including consequential damage due to reliance on any material contained in this handbook.   

King Pigeon Communication.Co.,Limited. its employees and distributors, accept no liability for GSM Network 

upgrading or SIMCard upgrading due to the technology specifications contained in this handbook.

 

Summary of Contents for GSM 3G M2M RTU

Page 1: ...GSM 3G IOT M2M Solution User Manual Ver 1 0 S27x Date Issued 2015 04 20 All rights reserved by King Pigeon Comm Co Limited www GSM M2M com GSM 3G M2M RTU ...

Page 2: ... USB cable 1x User Manual 1x Backup battery inside 1x TF card inside Terminals for Connection 4 The standard package not includes SIMCard Temperature Humidity sensor TH100 Warning Tips This User manual is for S275 for other models please refer to this user manual and note abovementioned differences This handbook has been designed as a guide to the installation and operation of RTU S27x Statements ...

Page 3: ...used as preset time when the GSM 3G M2M RTU need work and when it needn t work An Access Control unit Up to 10 tel numbers can be authorized for dial to access control and open the electricity door directly with free charge An automation system Each input can link to output actions this is very useful when the temperature upto appointed value need switch on the air conditioning immediately or when...

Page 4: ...visioning center the own can remote monitoring and control the remotely terminals by GPRS 3G RJ45 LAN Network This is very useful to Fuel tank monitoring Oxygen in hospital Flood level street light control wellhead control BTS environment monitoring power transmission system monitoring and other applications 1 1 Typically Applications Typically BTS Solution Diagram ...

Page 5: ...mA 4 20mA 5 4 Relay outputs 5A 30VDC 5A 250VAC 6 8 digital inputs dry contact or level input One of the input can be used as counter 7 1 temperature probe input 1 humidity transducer input 8 I O ports with opto isolated RS232 485 with 15KV ESD protection 9 2 IP data centers supports Modbus TCP TCP IP protocol over GPRS 3G RJ45 LAN network 10 RS232 RS485 can performs Modbus RTU Master Modbus RTU Sl...

Page 6: ...esolution 0 5V or 0 20mA or 4 20mA Temp Hum Inputs TH100 Range Temperature 40 C to 80 C Humidity 0 100 RH Relay Outputs 4 Rated 5A 30VDC 5A 250VAC Power Outputs 2 Port for external device Memory Capacity Internal Memory inside can save the data for 1000events Backup Battery 3 7V 1200mAH Temperature range 10 70 C Humidity range Relative humidity 95 condensation free Exterior dimension 168mm 113mm 3...

Page 7: ...r normally is off T H Temperature Humidity sensor TH100 inputs Power Connector Definition DC IN External Power Connector Connect to 1 5A 9 36V DC power through AC DC Adaptor positive electrode DC IN External Power Connector negative electrode DC Out See above mentioned photo Digital Relay Output Connector Definition DO Digital Relay Output 4 positive electrode NO GND Digital Relay Output 4 negativ...

Page 8: ...e Contact the unit to the PC by USB Cable and then install the USB Driver to the computer from the CD firstly When successful it can be found out at the device manager of the XP or Windows 7 please see the below photo Also the driver for different OS can be downloaded from Silicon Laboratories Inc http www silabs com the model is CP210x Step2 Connection Please insert the SIMCard and install the GS...

Page 9: ...uration page as below Step4 Configuration Parameters The GSM 3G M2M RTU configurator is a user friendly design software all of the parameters and ranges are describe clearly please read the notices carefully to save you configuration time Also for daily operate we are strongly recommend the user use the App 5 SMS commands APP The user can send SMS commands to setup or operate the GSM 3G M2M RTU al...

Page 10: ...er Goes OFF External DC Power Goes ON External DC Power Goes ON 3 Modify Password 4digits default is 1234 SMS Command Return SMS Content Old Password P New Password This is the New Password please remember it carefully 4 Arm Disarm SMS Command SMS Command Return SMS Content Arm password AA Armed Disarm password BB Disarmed 5 Set RTU time format is 2015 05 22 15 20 30W01 the W01 stands for Monday W...

Page 11: ...es number S start time E endtime Always can access control password B series number P Notice Time format is 201505231230 stands for year month date hour minute Tel1 Tel2 Tel3 13570810254 Tel4 Tel5 Inquiry password B Return all authorized user numbers Delete password B series number Return all authorized user numbers 9 Setup Daily Report time SMS Command Return SMS Content Setup password DR series ...

Page 12: ...AINM channel number DEL Inquiry AIN Current Value password AINE channel number nnnnnnnn AINx xxxx Normal Higher Lower Inquiry All AIN Current Value password AINE AIN0 xxxx Normal Higher Lower AIN1 xxxx Normal Higher Lower 12 SMS Control Digital Output SMS Command Return SMS Content Set DO Name password DO channel number T DOx xxxx Inquiry DO Name password DO channel number nnnn Delete DO Name pass...

Page 13: ...ations It is very useful for users to create remotely or local monitoring server It inbuilt standard Modbus RTU Modbus TCP transparent data transmission protocol and definition protocol the user can connect the GSM 3G M2M RTU to the present HMI OPC Server SCADA directly 6 1 Modbus RTU Modbus TCP Protocol The GSM 3G M2M RTU supports standard Modbus RTU and Modbus TCP protocol the user can use the s...

Page 14: ...oner generator meters instruments transducers sensors PLC and so on The user no need to create or change its present server protocol and can use it directly At this condition the GSM 3G M2M RTU performs a SMS Alarm and SMS Controller and DTU and Modbus RTU Slave The topological graphs please see below RTU Existing Server Modbus RTU Server Non Modbus RTU Meters or Devices Transparent Data Transmiss...

Page 15: ...e them directly by USB port if you required upgrade please contact us to modify the firmware according to you requirements and we will provide the upgraded firmware to you to upgrade them 9 Warranty 1 The RTU is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or m...

Reviews: